Effects of bathing solution on tensile properties of the cornea.

Hamed Hatami-Marbini1, Abdolrasol Rahimi2.   

Abstract

The cornea is a transparent tissue with the major functions of protecting the inner contents of the eye and refracting incoming light. The biomechanical properties of the cornea strongly depend on the microstructure and composition of the stromal layer, a hydrated bio-gel. The uniaxial strip testing is a convenient and well-accepted experimental technique for characterizing corneal material parameters. It is known that the water content of specimens in this method depends on the osmolality of the bathing solution. The present study was designed to investigate the effects of different bathing solutions on uniaxial tensile material properties of the cornea. The tensile behavior of bovine corneal samples was measured in six different bathing solutions, i.e., hypertonic solution (12% NaCl solution), common preserving isotonic solutions (e.g., phosphate buffer saline, ophthalmic balanced salt solution, and 0.9% NaCl solution), hypotonic solution (distilled water), and neutral solution (mineral oil). It was observed that the bathing solution had significant influence on the tensile behavior of the corneal samples. In particular, the specimens tested in bathing solutions causing less swelling had significantly stiffer tensile properties. Furthermore, a simple mathematical model based on Voigt composite material model was developed to represent the measured solution-dependent tensile properties. The present study suggests that extra attention should be paid to corneal thickness (hydration) in uniaxial tensile experiments. It also provides important data on tensile properties of the cornea; such information could significantly contribute to improving the accuracy of numerical predictions of corneal biomechanics.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  bovine; cornea; stress–strain behavior; uniaxial tensile experiments

Mesh:

Substances:

Year:  2013        PMID: 24333541     DOI: 10.1016/j.exer.2013.11.017

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  11 in total

1.  Plastic modification of the cornea by pneumatic force corrects myopia: Pneumatic keratology.

Authors:  A Medina
Journal:  Eye (Lond)       Date:  2017-06-16       Impact factor: 3.775

2.  Corneal Hydration Control during Ex Vivo Experimentation Using Poloxamers.

Authors:  Keyton Clayson; Thomas Sandwisch; Yanhui Ma; Elias Pavlatos; Xueliang Pan; Jun Liu
Journal:  Curr Eye Res       Date:  2019-09-18       Impact factor: 2.424

3.  Changing material properties of the tree shrew sclera during minus lens compensation and recovery.

Authors:  Rafael Grytz; John T Siegwart
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-03-03       Impact factor: 4.799

4.  Impact of Hydration Media on Ex Vivo Corneal Elasticity Measurements.

Authors:  Janice Dias; Noël M Ziebarth
Journal:  Eye Contact Lens       Date:  2015-09       Impact factor: 2.018

5.  Analysis of the viscoelastic properties of the human cornea using Scheimpflug imaging in inflation experiment of eye globes.

Authors:  Giuseppe Lombardo; Sebastiano Serrao; Marianna Rosati; Marco Lombardo
Journal:  PLoS One       Date:  2014-11-14       Impact factor: 3.240

6.  Corneal pulsation and biomechanics during induced ocular pulse. An ex-vivo pilot study.

Authors:  Maja M Rogala; Daniel Lewandowski; Jerzy Detyna; Agnieszka Antończyk; Monika E Danielewska
Journal:  PLoS One       Date:  2020-02-13       Impact factor: 3.240

7.  Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness.

Authors:  Elizabeth M Boazak; Rebecca King; Jiaxing Wang; Cassandra M Chu; Aaron M Toporek; Joseph M Sherwood; Darryl R Overby; Eldon E Geisert; C Ross Ethier
Journal:  Front Bioeng Biotechnol       Date:  2021-02-05

8.  Tensile Viscoelastic Properties of the Sclera after Glycosaminoglycan Depletion.

Authors:  Hamed Hatami-Marbini; Mohammad Pachenari
Journal:  Curr Eye Res       Date:  2021-07-30       Impact factor: 2.555

Review 9.  Mechanobiology of the corneal epithelium.

Authors:  Sophia Masterton; Mark Ahearne
Journal:  Exp Eye Res       Date:  2018-08-04       Impact factor: 3.467

10.  The contribution of sGAGs to stress-controlled tensile response of posterior porcine sclera.

Authors:  Hamed Hatami-Marbini; Mohammad Pachenari
Journal:  PLoS One       Date:  2020-02-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.