Literature DB >> 24332974

Clinical application of 3D VIBECAIPI-DIXON for non-enhanced imaging of the pancreas compared to a standard 2D fat-saturated FLASH.

Stefan Haneder1, Katrin Koziel1, John N Morelli2, Philipp Riffel1, Johannes Budjan3, Stefan O Schoenberg1, Henrik J Michaely1.   

Abstract

PURPOSE: To compare a fast 3D VIBE sequence with Dixon fat saturation and CAIPIRINHA acceleration techniques (3D VIBE(CAIPI-DIXON)) to a standard 2D FLASH sequence with spectral fat saturation and conventional GRAPPA acceleration technique (2D Flash(GRAPPA-fs)) for non-enhanced imaging of the pancreas. METHODS AND MATERIALS: In this retrospective, institutional review board-approved intra-individual comparison study, 29 patients (7 female, 22 male; mean age 60.4 ± 20.9 years) examined on a 48-channel 3.0-T MR system (MAGNETOM Skyra VD 13, Siemens Healthcare Sector, Germany) were included. 3D VIBE(CAIPI-DIXON) (TR/TE-3.95/2.5+1.27 ms; spatial resolution-1.2 × 1.2 × 3.0 mm(3); CAIPIRINHA 2 × 2 [1], acquisition time-0:12 min) and 2D Flash(GRAPPA-fs) (TR/TE-195/3.69 ms; 1.2 × 1.2 × 3.0 mm(3); GRAPPA 2, 3 × 0:21 min) sequences were performed in each subject in random order prior to the administration of an intravenous contrast agent. Two radiologists evaluated the images with regard to diagnostic preference. Semi-quantitative signal ratios were calculated for the pancreas versus the liver, spleen, muscle, and visceral fat. Inter-reader agreement was calculated using unweighted Cohen's kappa. Signal ratio results were analyzed using a univariate analysis of variance. Additional signal-to-noise (SNR) measurements were performed in a phantom.
RESULTS: 3D VIBE(CAIPI-DIXON) was preferred in 72.4% (both readers) and 2D Flash(GRAPPA-fs) in 3.4%/6.9% (reader 1/2) of cases with a kappa value of 0.756. The main reasons for this preference were homogenous fat saturation with 3D VIBE(CAIPI-DIXON) and reduced motion artifacts due to a faster acquisition, leading to improved delineation of the pancreas. Signal ratios of pancreatic to fat signal for 3D VIBE(CAIPI-DIXON) (10.08 ± 3.48) and 2D Flash(GRAPPA-fs) (6.53 ± 3.07) were statistically different (P<.001). However, no additional statistically significant differences in signal ratios were identified (range: 0.73 ± 0.18 to 1.37 ± 0.40; .514<P<.961). SNR did not statistically significantly differ between the sequences.
CONCLUSION: 3D VIBE(CAIPI-DIXON) enables robust pancreatic imaging with a shorter time and improved fat suppression relative to conventional 2D Flash(GRAPPA-fs). At an acquisition time of 12 seconds, 3D VIBE(CAIPI-DIXON) can be obtained in considerably less time than standard fat-saturated VIBE sequences.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CAIPIRINHA; Dixon; T1-weighted imaging; fat-saturation; pancreas

Mesh:

Substances:

Year:  2013        PMID: 24332974     DOI: 10.1016/j.clinimag.2013.11.005

Source DB:  PubMed          Journal:  Clin Imaging        ISSN: 0899-7071            Impact factor:   1.605


  5 in total

1.  Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging.

Authors:  Thomas Benkert; Kai Tobias Block; Samantha Heller; Melanie Moccaldi; Daniel K Sodickson; Sungheon Gene Kim; Linda Moy
Journal:  Invest Radiol       Date:  2017-10       Impact factor: 6.016

2.  Fat-only Dixon: how to use it in body MRI.

Authors:  Reza Salari; David H Ballard; Mark J Hoegger; Daniel Young; Anup S Shetty
Journal:  Abdom Radiol (NY)       Date:  2022-05-18

3.  Fast MR Imaging of the Paediatric Abdomen with CAIPIRINHA-Accelerated T1w 3D FLASH and with High-Resolution T2w HASTE: A Study on Image Quality.

Authors:  Mengxia Li; Beate Winkler; Thomas Pabst; Thorsten Bley; Herbert Köstler; Henning Neubauer
Journal:  Gastroenterol Res Pract       Date:  2015-04-07       Impact factor: 2.260

4.  Rapid Cartesian versus radial acquisition: comparison of two sequences for hepatobiliary phase MRI at 3 tesla in patients with impaired breath-hold capabilities.

Authors:  Johannes Budjan; Philipp Riffel; Melissa M Ong; Stefan O Schoenberg; Ulrike I Attenberger; Daniel Hausmann
Journal:  BMC Med Imaging       Date:  2017-05-09       Impact factor: 1.930

5.  The efficacy of the 3-dimensional vibe-caipirinha-dixon technique in the evaluation of pancreatic steatosis

Authors:  Ural Koç; Gökhan Ocakoğlu; Oktay Alğin
Journal:  Turk J Med Sci       Date:  2020-02-13       Impact factor: 0.973

  5 in total