Literature DB >> 24332812

Intraprocedural retrieval of migrated coils during endovascular aneurysm treatment with the Trevo Stentriever device.

Kenneth C Liu1, Dale Ding2, Robert M Starke2, Scott R Geraghty3, Mary E Jensen4.   

Abstract

Coil migration during endovascular treatment of intracranial aneurysms occurs in 2-6% of cases. As endovascular coiling of aneurysms has become increasingly popular and as endovascular technology continues to rapidly evolve, the prevalence of intraprocedural coil migration will invariably rise. Since coil masses are highly thrombogenic, migration out of the aneurysm sac into the parent artery may result in large territory infarcts which subsequently manifest as significant neurological morbidity. Therefore safe and timely retrieval of migrated coils is essential to avoiding poor angiographic and clinical outcomes. A 66-year-old woman with an unruptured 5 × 3mm, wide-necked posterior communicating artery aneurysm was referred for endovascular treatment. During coiling with the dual catheter technique, both initially deployed coils dislodged from the aneurysm sac and migrated distally into the middle cerebral artery. After failed retrieval with an Alligator device (Chestnut Medical Technologies, Menlo Park, CA, USA), we used two Trevo devices (Concentric Medical, Mountain View, CA, USA) in succession to successfully retrieve the migrated coils. The aneurysm was then occluded with stent-assisted coil embolization. There were no post-procedural angiographic or clinical complications. The patient was subsequently discharged home without neurological deficit. This case illustrates the first use of the Trevo device for retrieval of migrated coils during endovascular treatment of an intracranial aneurysm to our knowledge. Due to the lack of guidelines defining the standard management of intraprocedural coil migration, current strategies are based on retrospective review of published reports and expert opinion. We present a unique and effective method for endovascular retrieval of displaced coils using a Trevo Stentriever device.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Endovascular procedures; Intracranial aneurysm; Intraoperative complications; Stents; Stroke

Mesh:

Year:  2013        PMID: 24332812     DOI: 10.1016/j.jocn.2013.10.012

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  15 in total

1.  Magnetic wires: A novel design for neuroendovascular coil retrieval.

Authors:  Lingyun Zhang; Yugang Jiang
Journal:  Exp Ther Med       Date:  2018-07-23       Impact factor: 2.447

2.  Inadvertent Stent Retriever Detachment: A Multicenter Case Series and Review of Device Experience FDA Reports.

Authors:  Hesham Masoud; Thanh N Nguyen; Coleman O Martin; William E Holloway; Sudheer Ambekar; Dileep R Yavagal; Diogo C Haussen; Raul Nogueira; Diego J Lozano; Ajit Puri; Ayman Quateen; Daniela Iancu; Michael G Abraham; Michael Chen; Sonal Mehta; Tim Malisch; Franklin Marden; Robin Novakovic; Daniel Roy; Alain Weill; Alexander M Norbash
Journal:  Interv Neurol       Date:  2015-11-20

3.  Retrieval of unintended migrated detached coil: case report.

Authors:  Jiwoong Oh; Jongyun Kim; Sunki Hong; Chul Hu; Jinsu Pyen; Kum Whang; Sungmin Cho; Do-Sung You
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2014-09-30

4.  Retrieval of Migrated Volume Coils Using Different Clot Retrievers in a Porcine Model.

Authors:  Andreas Simgen; Toshiki Tomori; Ruben Mühl-Benninghaus; Hagen Bomberg; Umut Yilmaz; Heiko Körner; Matthias W Laschke; Michael D Menger; Wolfgang Reith
Journal:  Clin Neuroradiol       Date:  2017-06-01       Impact factor: 3.649

Review 5.  Evolution of endovascular mechanical thrombectomy for acute ischemic stroke.

Authors:  Colin J Przybylowski; Dale Ding; Robert M Starke; Christopher R Durst; R Webster Crowley; Kenneth C Liu
Journal:  World J Clin Cases       Date:  2014-11-16       Impact factor: 1.337

Review 6.  Endovascular Stroke Interventions: Procedural Complications and Management.

Authors:  Ahmed Elakkad; Gerald Drocton; Ferdinand Hui
Journal:  Semin Intervent Radiol       Date:  2020-05-14       Impact factor: 1.513

7.  Retrieval of migrated coils with stent retrievers: an animal study.

Authors:  O Nikoubashman; R Pjontek; M-A Brockmann; R Tolba; M Wiesmann
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-12       Impact factor: 3.825

8.  Rescue Therapy of Inadvertent Coil Migration for Endovascular Treatment of Type II Endoleak.

Authors:  Kanghaeng Lee; Hyung Sub Park; Taeseung Lee
Journal:  Vasc Specialist Int       Date:  2016-03-31

9.  Retrieval of Distally Migrated Coils with Detachable Intracranial Stent during Coil Embolization of Cerebral Aneurysm.

Authors:  Devendra Pal Singh; Soon Chan Kwon; Lijin Huang; Won Joo Lee
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2016-03-31

10.  Endovascular Management of Intracranial Aneurysms: Advances in Stenting Techniques and Technology.

Authors:  Dale Ding
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2015-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.