Literature DB >> 24331050

Quantitation of low concentrations of polysorbates in high protein concentration formulations by solid phase extraction and cobalt-thiocyanate derivatization.

Justin Kim1, Jinshu Qiu2.   

Abstract

A spectrophotometric method was developed to quantify low polysorbate (PS) levels in biopharmaceutical formulations containing high protein concentrations. In the method, Oasis HLB solid phase extraction (SPE) cartridge was used to extract PS from high protein concentration formulations. After loading a sample, the cartridge was washed with 4M guanidine HCl and 10% (v/v) methanol, and the retained PS was eluted by acetonitrile. Following the evaporation of acetonitrile, aqueous cobalt-thiocyanate reagent was added to react with the polyoxyethylene oxide chain of polysorbates to form a blue colored PS-cobaltothiocyante complex. This colored complex was then extracted into methylene chloride and measured spectrophotometrically at 620 nm. The method performance was evaluated on three products containing 30-40 mg L(-1) PS-20 and PS-80 in ≤70 g L(-1) protein formulations. The method was specific (no matrix interference identified in three types of protein formulations), sensitive (quantitation limit of 10 mg L(-1) PS) and robust with good precision (relative standard deviation ≤6.4%) and accuracy (spike recoveries from 95% to 101%). The linear range of the method for both PS-20 and PS-80 was 10 to 80 mg L(-1) PS. By diluting samples with 6M guanidine HCl and/or using different methylene chloride volumes to extract the colored complexes of standards and samples, the method could accurately and precisely quantify 40 mg L(-1) PS in up to 300 g L(-1) protein formulations.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Abs; Cobalt-thiocyanate; DS; High protein concentration formulations; Monoclonal antibody; PS; Polysorbate 20; Polysorbate 80; RSD; SD; SPE; Solid phase extraction; UF/DF; absorbance; drug substance; mAb; monoclonal antibody; polysorbate; relative standard deviation; solid phase extraction; standard deviation; ultrafiltration/diafiltration

Mesh:

Substances:

Year:  2013        PMID: 24331050     DOI: 10.1016/j.aca.2013.11.005

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

Review 1.  Considerations for the Use of Polysorbates in Biopharmaceuticals.

Authors:  Michael T Jones; Hanns-Christian Mahler; Sandeep Yadav; Dilbir Bindra; Vincent Corvari; R Matthew Fesinmeyer; Kapil Gupta; Alexander M Harmon; Kenneth D Hinds; Atanas Koulov; Wei Liu; Kevin Maloney; John Wang; Ping Y Yeh; Satish K Singh
Journal:  Pharm Res       Date:  2018-05-24       Impact factor: 4.200

2.  Universal method for the determination of nonionic surfactant content in the presence of protein.

Authors:  Ziping Wei; Susanna Bilbulian; Jingning Li; Ratnesh Pandey; Ellen O'Connor; Jose Casas-Finet; Patricia W Cash
Journal:  J Sep Sci       Date:  2015-03-03       Impact factor: 3.645

  2 in total