Literature DB >> 24330219

Achieving consensus in ultrasonography synovitis scoring in rheumatoid arthritis.

Peter P Cheung1, Kok Ooi Kong, Li-Ching Chew, Faith L Chia, Weng Giap Law, Tsui Yee Lian, York Kiat Tan, Yew Kuang Cheng.   

Abstract

OBJECTIVE: Ultrasonography is sensitive for synovitis detection but interobserver variation in both acquisition and image interpretation is still a concern. The objective was to assess if a short collegiate consensus would improve inter-observer reliability in scoring of synovitis.
METHODS: Eight rheumatologists (Singapore) participated in a 1-day consensus meeting divided into: (i) still-image interpretation and consensus followed by; (ii) image acquisition and interpretation, according to definitions and synovitis scoring rules endorsed by Outcome Measures in Rheumatology (OMERACT) and TUI (Targeted Ultrasound Initiative). Interobserver reliability of semiquantitative scoring in B-mode, Power Doppler (PDUS) and European League Against Rheumatism (EULAR)-OMERACT PDUS composite score was assessed by intraclass correlation co-efficient (ICC). Agreement at the joint region level was calculated using prevalence-adjusted-biased-adjusted-kappa (PABAK).
RESULTS: For B-mode still images, ICC was good at 0.75 (95% CI 0.66-0.82) while for PDUS images this was excellent at ICC = 0.88 (95% CI 0.83-0.92) with ICC improving by 12% for B-mode and 13% for PDUS respectively. During image acquisition and interpretation, B-mode scoring showed ICC = 0.75 (95% CI 0.66-0.84) while for PDUS the ICC was lower at 0.59 (95% CI 0.48-0.72). The ICC for OMERACT PDUS composite synovitis scoring was good at 0.77 (95% CI 0.68-0.85). At the joint level, agreement varied with PABAK being excellent in the small joints of the hands but poor to fair in the wrists, elbows, ankles and metatarsophalangeal joints, and no agreement at the knees (PABAK range -0.34 to 0.85).
CONCLUSION: A consensus meeting was useful in improving interobserver variation in US synovitis scoring of still images, but image acquisition and interpretation especially in non-hand joints require further standardization.
© 2013 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

Entities:  

Keywords:  reliability; rheumatoid arthritis; synovitis; ultrasonography

Mesh:

Year:  2013        PMID: 24330219     DOI: 10.1111/1756-185X.12247

Source DB:  PubMed          Journal:  Int J Rheum Dis        ISSN: 1756-1841            Impact factor:   2.454


  3 in total

1.  Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists.

Authors:  Lucio Ventura-Ríos; Cristina Hernández-Díaz; Diana Ferrusquia-Toríz; Esteban Cruz-Arenas; Pedro Rodríguez-Henríquez; Ana Laura Alvarez Del Castillo; Alfredo Campaña-Parra; Efrén Canul; Gerardo Guerrero Yeo; Juan Jorge Mendoza-Ruiz; Mario Pérez Cristóbal; Sandra Sicsik; Karina Silva Luna
Journal:  Clin Rheumatol       Date:  2017-05-05       Impact factor: 2.980

2.  Comparison of the clinical effectiveness of US grading scoring system vs MRI in the diagnosis of early rheumatoid arthritis (RA).

Authors:  Huajun Xu; Yingchun Zhang; Huimei Zhang; Caishan Wang; Pan Mao
Journal:  J Orthop Surg Res       Date:  2017-10-17       Impact factor: 2.359

3.  Musculoskeletal ultrasound in hemophilia: Results and recommendations from a global survey and consensus meeting.

Authors:  Nihal Bakeer; Saunya Dover; Paul Babyn; Brian M Feldman; Annette von Drygalski; Andrea S Doria; Danial M Ignas; Audrey Abad; Cindy Bailey; Ian Beggs; Eric Y Chang; Amy Dunn; Sharon Funk; Sridhar Gibikote; Nicholas Goddard; Pamela Hilliard; Shyamkumar N Keshava; Rebecca Kruse-Jarres; Yingjia Li; Sébastien Lobet; Marilyn Manco-Johnson; Carlo Martinoli; James S O'Donnell; Olympia Papakonstantinou; Helen Pergantou; Pradeep Poonnoose; Felipe Querol; Alok Srivastava; Bruno Steiner; Karen Strike; Merel Timmer; Pascal N Tyrrell; Logi Vidarsson; Victor S Blanchette
Journal:  Res Pract Thromb Haemost       Date:  2021-07-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.