Evaluation of Risk Factors for Glaucoma Drainage Device-related Erosions: A Retrospective Case-Control Study.

Valerie Trubnik1, Camila Zangalli, Marlene R Moster, Thomas Chia, Mohsin Ali, Patricia Martinez, Jesse Richman, Jonathan S Myers.   

Abstract

PURPOSE: To identify risk factors for glaucoma drainage device (GDD) erosions. PATIENTS AND METHODS: In a retrospective comparative case series, medical records of 1013 patients who underwent GDD surgery performed by 5 surgeons between 2006 and 2011 were reviewed. The outcome measures assessed included age, race, sex, contact lens wear, seasonal allergies, medical comorbidities, glaucoma diagnosis, preoperative oral and topical medications, type and number of preoperative surgeries and lasers, concomitant surgeries, tube type and position, patch graft material, and intraoperative use of Avastin, mitomycin-C, or Triescence. The association of variables with erosion status was evaluated using the Fisher exact test for categorical variables and the exact Wilcoxon rank-sum test for continuous variables.
RESULTS: Charts were included from 339 eyes that had complete data sets and at least 6 months of follow-up. Twenty-eight eyes (8.3%) developed conjunctival erosions. The median follow-up time was 2.03 years for the erosion group and 1.71 years for nonerosion group. Erosion was only associated with the presence of concomitant surgical procedures at the time of GDD implantation (35.7% erosion group vs. 17.4% nonerosion group, P=0.02, OR=2.64). The majority of concomitant surgeries were composed of pars plana vitrectomy (35.0%) and cataract surgery (32.0%). Variables that were suggestive of association with erosion (P<0.20) included smoking (OR=2.14), pseudoexfoliation glaucoma (OR=2.71), and history of dry eye syndrome (OR=2.22).
CONCLUSION: History of concomitant intraocular surgery with GDD implantation may be a potential risk factor for future erosions.

Entities:  

Mesh:

Year:  2015        PMID: 24326968     DOI: 10.1097/IJG.0000000000000034

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  17 in total

1.  Baerveldt® glaucoma implant surgery with the double scleral flap technique to prevent Hoffman elbow exposure.

Authors:  Naoki Tojo; Tomoko Ueda-Consolvo; Shuichiro Yanagisawa; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-07-22       Impact factor: 3.117

Review 2.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

3.  Comparison of complications after Ahmed versus Baerveldt implant in glaucoma patients: one year follow-up.

Authors:  Sara Listyani Koentjoro; Widya Artini; Iwan Soebijantoro; Vira Wardhana Istiantoro; Emma Rusmayani; Rini Sulastiwaty; Zeiras Eka Djamal; Arini Safira Nurul Akbar; Muhammad Yoserizal
Journal:  Int J Ophthalmol       Date:  2020-12-18       Impact factor: 1.779

4.  Clinical outcomes of gamma-irradiated sterile cornea in aqueous drainage device surgery: a multicenter retrospective study.

Authors:  Q Pan; H D Jampel; P Ramulu; G F Schwartz; F Cotter; D Cute; Y J Daoud; P Murakami; W J Stark
Journal:  Eye (Lond)       Date:  2016-11-11       Impact factor: 3.775

5.  Outcomes of the Shunt Tube Exposure Prevention Study: A Randomized Clinical Trial.

Authors:  Hosam Sheha; Celso Tello; Lama A Al-Aswad; Mohamed S Sayed; Richard K Lee
Journal:  Ophthalmol Glaucoma       Date:  2019-08-16

6.  Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft).

Authors:  Feyzahan Ekici; Marlene R Moster; Victor Cvintal; Wanda D Hu; Michael Waisbourd
Journal:  Clin Ophthalmol       Date:  2015-05-04

7.  Risk factors for exposure of glaucoma drainage devices: a retrospective observational study.

Authors:  Kelly W Muir; Annie Lim; Sandra Stinnett; Anthony Kuo; Henry Tseng; Molly M Walsh
Journal:  BMJ Open       Date:  2014-05-02       Impact factor: 2.692

8.  Baerveldt Scleral Patch Graft Abscess Secondary to Coagulase-Negative Staphylococcus.

Authors:  Van Nguyen; Mason Schmutz; Sarah Farukhi; Sameh Mosaed
Journal:  Case Rep Ophthalmol       Date:  2017-11-17

Review 9.  Ahmed glaucoma valve implant: surgical technique and complications.

Authors:  Ivano Riva; Gloria Roberti; Francesco Oddone; Anastasios Gp Konstas; Luciano Quaranta
Journal:  Clin Ophthalmol       Date:  2017-02-17

10.  Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery.

Authors:  Meenakshi Chaku; Peter A Netland; Kyoko Ishida; Douglas J Rhee
Journal:  Clin Ophthalmol       Date:  2016-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.