Literature DB >> 24321401

The novel application of Benford's second order analysis for monitoring radiation output in interventional radiology.

S Cournane1, N Sheehy2, J Cooke3.   

Abstract

Benford's law is an empirical observation which predicts the expected frequency of digits in naturally occurring datasets spanning multiple orders of magnitude, with the law having been most successfully applied as an audit tool in accountancy. This study investigated the sensitivity of the technique in identifying system output changes using simulated changes in interventional radiology Dose-Area-Product (DAP) data, with any deviations from Benford's distribution identified using z-statistics. The radiation output for interventional radiology X-ray equipment is monitored annually during quality control testing; however, for a considerable portion of the year an increased output of the system, potentially caused by engineering adjustments or spontaneous system faults may go unnoticed, leading to a potential increase in the radiation dose to patients. In normal operation recorded examination radiation outputs vary over multiple orders of magnitude rendering the application of normal statistics ineffective for detecting systematic changes in the output. In this work, the annual DAP datasets complied with Benford's first order law for first, second and combinations of the first and second digits. Further, a continuous 'rolling' second order technique was devised for trending simulated changes over shorter timescales. This distribution analysis, the first employment of the method for radiation output trending, detected significant changes simulated on the original data, proving the technique useful in this case. The potential is demonstrated for implementation of this novel analysis for monitoring and identifying change in suitable datasets for the purpose of system process control.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Benford's law; Interventional radiology; Radiation dose

Mesh:

Year:  2013        PMID: 24321401     DOI: 10.1016/j.ejmp.2013.11.004

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  1 in total

1.  Generalized Benford's Law as a Lie Detector.

Authors:  Nicolas Gauvrit Gauvrit; Jean-Charles Houillon; Jean-Paul Delahaye
Journal:  Adv Cogn Psychol       Date:  2017-06-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.