Kirsten M Kooiman1, Reinoud E Knops1, Louise Olde Nordkamp1, Arthur A M Wilde1, Joris R de Groot2. 1. Heart Center, Department of Clinical and Experimental Cardiology, Academic Medical Center, Amsterdam, The Netherlands. 2. Heart Center, Department of Clinical and Experimental Cardiology, Academic Medical Center, Amsterdam, The Netherlands. Electronic address: j.r.degroot@amc.uva.nl.
Abstract
BACKGROUND: Inappropriate shocks (IASs) complicate implantable cardioverter-defibrillator (ICD) therapy. The management of IASs in patients with a subcutaneous ICD (S-ICD) differs from that in patients with a conventional ICD because of different sensing algorithms and programming options. OBJECTIVE: To describe the management of IASs in patients with an S-ICD. METHODS: Patients were implanted with an S-ICD between February 2009 and July 2012. The prevalence data and clinical determinants of IASs were prospectively collected. In the case of T-wave oversensing (TWOS), an exercise test was performed, and all possible sensing vectors were screened for TWOS. The absence of TWOS defined a suitable vector. RESULTS: Eleven of 69 patients (54% men; mean age 39 ± 14 years; 73% primary prevention) received IASs after 8.9 ± 10 months of implantation (10.8% annual incidence rate). In 8 cases, TWOS caused IASs. Seven of these IASs occurred during exercise and 1 during atrial fibrillation with a high ventricular rate. To manage TWOS, in 7 of 8 patients the sensing vector was changed and in 5 of 8 patients the (un)conditional zone was changed. Hereafter, IASs recurred in 3 of 8 patients, in 2 because of programming errors. Hence, after reprogramming, we observed no IASs in 87.5% of the patients with TWOS during a follow-up of 14.1 ± 13 months. CONCLUSIONS: IASs due to TWOS in the S-ICD can be managed by reprogramming the sensing vector and/or the therapy zones of the device using a template acquired during exercise. Exercise-optimized programming can reduce future IASs, and standard exercise testing shortly after the implantation of an S-ICD may be considered in patients at an increased risk for TWOS.
BACKGROUND: Inappropriate shocks (IASs) complicate implantable cardioverter-defibrillator (ICD) therapy. The management of IASs in patients with a subcutaneous ICD (S-ICD) differs from that in patients with a conventional ICD because of different sensing algorithms and programming options. OBJECTIVE: To describe the management of IASs in patients with an S-ICD. METHODS:Patients were implanted with an S-ICD between February 2009 and July 2012. The prevalence data and clinical determinants of IASs were prospectively collected. In the case of T-wave oversensing (TWOS), an exercise test was performed, and all possible sensing vectors were screened for TWOS. The absence of TWOS defined a suitable vector. RESULTS: Eleven of 69 patients (54% men; mean age 39 ± 14 years; 73% primary prevention) received IASs after 8.9 ± 10 months of implantation (10.8% annual incidence rate). In 8 cases, TWOS caused IASs. Seven of these IASs occurred during exercise and 1 during atrial fibrillation with a high ventricular rate. To manage TWOS, in 7 of 8 patients the sensing vector was changed and in 5 of 8 patients the (un)conditional zone was changed. Hereafter, IASs recurred in 3 of 8 patients, in 2 because of programming errors. Hence, after reprogramming, we observed no IASs in 87.5% of the patients with TWOS during a follow-up of 14.1 ± 13 months. CONCLUSIONS: IASs due to TWOS in the S-ICD can be managed by reprogramming the sensing vector and/or the therapy zones of the device using a template acquired during exercise. Exercise-optimized programming can reduce future IASs, and standard exercise testing shortly after the implantation of an S-ICD may be considered in patients at an increased risk for TWOS.
Authors: Pau Alonso; Joaquín Osca; Joaquín Rueda; Oscar Cano; Pedro Pimenta; Ana Andres; María José Sancho; Luis Martinez Journal: Ann Noninvasive Electrocardiol Date: 2017-05-15 Impact factor: 1.468
Authors: Badder Kattih; David Duncker; Thorben König; Stephan Hohmann; Hanno Oswald; Christian Veltmann Journal: Herzschrittmacherther Elektrophysiol Date: 2016-04-15
Authors: Vincent C Thomas; Mark Peterson; Martin McDaniel; Humberto Restrepo; Abraham Rothman; Amit Jain Journal: Pediatr Cardiol Date: 2017-05-22 Impact factor: 1.655