Literature DB >> 24320741

Procedure for microbial identification based on Matrix-Assisted Laser Desorption/Ionization-Time of Flight Mass Spectrometry from screening-positive urine samples.

Gabriel A March Rosselló1, María P Gutiérrez Rodríguez, Raúl Ortiz de Lejarazu Leonardo, Antonio Orduña Domingo, Miguel A Bratos Pérez.   

Abstract

Matrix-Assisted Laser Desorption/Ionization-Time of Flight Mass Spectrometry is a widely used proteomic technique in clinical microbiology laboratories, and enables microbial identification directly from clinical samples. This study seeks to establish a protocol for bacterial identification from monomicrobial urine samples that have tested positive in the screening with Sysmex UF-1000i (Sysmex Corporation, Kobe, Japan). Sysmex UF-1000i counts ≥1 × 10(7) bacteria/mL indicate a sufficient bacterial concentration to allow direct identification from urine, with 87.5% sensitivity. Microbial identification from urine with Sysmex UF-1000i counts between 1 × 10(5) and 1 × 10(7) bacteria/ml requires preincubation to obtain the adequate amount of bacteria needed for analysis, and 91.7% sensitivity thus being achieved.
© 2013 APMIS. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  MALDI-TOF; direct identification; urine

Mesh:

Year:  2013        PMID: 24320741     DOI: 10.1111/apm.12208

Source DB:  PubMed          Journal:  APMIS        ISSN: 0903-4641            Impact factor:   3.205


  8 in total

1.  NaOH-HCl neutralized urine preparation for direct testing of uropathogens by Bruker MS.

Authors:  Ji Seon Choi; Jayoung Kim; Han-Soo Kim; Chang-Wan Kwon; Min-Sung Kim; Seong-Hyeok Choi
Journal:  J Clin Lab Anal       Date:  2017-06-26       Impact factor: 2.352

2.  Implementation of a New Protocol for Direct Identification from Urine in the Routine Microbiological Diagnosis.

Authors:  Yuliya Zboromyrska; Verónica Rico; Cristina Pitart; Mariana José Fernández-Pittol; Álex Soriano; Jordi Bosch
Journal:  Antibiotics (Basel)       Date:  2022-04-26

3.  Accuracy of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for direct bacterial identification from culture-positive urine samples.

Authors:  Bin Sun; Wei Wang; Ping Ma; Bing Gu
Journal:  Ann Transl Med       Date:  2021-04

Review 4.  Confounding factors and genetic polymorphism in the evaluation of individual steroid profiling.

Authors:  Tiia Kuuranne; Martial Saugy; Norbert Baume
Journal:  Br J Sports Med       Date:  2014-05       Impact factor: 13.800

5.  A multicentre study investigating parameters which influence direct bacterial identification from urine.

Authors:  Yuliya Zboromyrska; Jordi Bosch; Jesus Aramburu; Juan Cuadros; Carlos García-Riestra; Julia Guzmán-Puche; Carmen Liébana Martos; Elena Loza; María Muñoz-Algarra; Carlos Ruiz de Alegría; Victoria Sánchez-Hellín; Jordi Vila
Journal:  PLoS One       Date:  2018-12-11       Impact factor: 3.240

Review 6.  Progress in Automated Urinalysis.

Authors:  Matthijs Oyaert; Joris Delanghe
Journal:  Ann Lab Med       Date:  2019-01       Impact factor: 3.464

7.  Evaluation of flow cytometry for the detection of bacteria in biological fluids.

Authors:  Elisa Rubio; Yuliya Zboromyrska; Jordi Bosch; Mariana J Fernandez-Pittol; Berta I Fidalgo; Assumpta Fasanella; Anna Mons; Angely Román; Climent Casals-Pascual; Jordi Vila
Journal:  PLoS One       Date:  2019-08-07       Impact factor: 3.240

8.  The use of Matrix-assisted laser desorption ionization-time of flight mass spectrometry in the identification of Francisella tularensis.

Authors:  Onur Karatuna; Bekir Celebi; Simge Can; Isin Akyar; Selcuk Kilic
Journal:  Bosn J Basic Med Sci       Date:  2016-01-15       Impact factor: 3.363

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.