Arbitrary magnetic field gradient waveform correction using an impulse response based pre-equalization technique.

Frédéric G Goora1, Bruce G Colpitts2, Bruce J Balcom3.   

Abstract

The time-varying magnetic fields used in magnetic resonance applications result in the induction of eddy currents on conductive structures in the vicinity of both the sample under investigation and the gradient coils. These eddy currents typically result in undesired degradations of image quality for MRI applications. Their ubiquitous nature has resulted in the development of various approaches to characterize and minimize their impact on image quality. This paper outlines a method that utilizes the magnetic field gradient waveform monitor method to directly measure the temporal evolution of the magnetic field gradient from a step-like input function and extracts the system impulse response. With the basic assumption that the gradient system is sufficiently linear and time invariant to permit system theory analysis, the impulse response is used to determine a pre-equalized (optimized) input waveform that provides a desired gradient response at the output of the system. An algorithm has been developed that calculates a pre-equalized waveform that may be accurately reproduced by the amplifier (is physically realizable) and accounts for system limitations including system bandwidth, amplifier slew rate capabilities, and noise inherent in the initial measurement. Significant improvements in magnetic field gradient waveform fidelity after pre-equalization have been realized and are summarized.
Copyright © 2013 Elsevier Inc. All rights reserved.

Keywords:  Eddy currents; Impulse response; Magnetic field gradient waveform correction; Optimal gradient waveforms; Pre-equalization

Mesh:

Year:  2013        PMID: 24316188     DOI: 10.1016/j.jmr.2013.11.003

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  4 in total

1.  Real-time distortion correction of spiral and echo planar images using the gradient system impulse response function.

Authors:  Adrienne E Campbell-Washburn; Hui Xue; Robert J Lederman; Anthony Z Faranesh; Michael S Hansen
Journal:  Magn Reson Med       Date:  2015-06-26       Impact factor: 4.668

2.  Field camera versus phantom-based measurement of the gradient system transfer function (GSTF) with dwell time compensation.

Authors:  M Stich; J A J Richter; T Wech; T A Bley; R Ringler; H Köstler; A E Campbell-Washburn
Journal:  Magn Reson Imaging       Date:  2020-06-10       Impact factor: 2.546

3.  Efficient gradient waveform measurements with variable-prephasing.

Authors:  Kevin D Harkins; Mark D Does
Journal:  J Magn Reson       Date:  2021-02-20       Impact factor: 2.734

4.  Accurate Measurement of Magnetic Resonance Imaging Gradient Characteristics.

Authors:  Hui Liu; Gerald B Matson
Journal:  Materials (Basel)       Date:  2014       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.