Literature DB >> 24315879

High-sensitivity paracetamol sensor based on Pd/graphene oxide nanocomposite as an enhanced electrochemical sensing platform.

Junhua Li1, Jinlong Liu2, Gongrong Tan2, Jianbo Jiang2, Sanjun Peng2, Miao Deng2, Dong Qian3, Yonglan Feng4, Youcai Liu5.   

Abstract

Well-dispersed Pd nanoparticles were facilely anchored on graphene oxide (Pd/GO) via a one-pot chemical reduction of the Pd(2+) precursor without any surfactants and templates. The morphology and composition of the Pd/GO nanocomposite were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR) and energy dispersive analysis of X-ray (EDX). The stepwise fabrication process of the Pd/GO modified electrode and its electrochemical sensing performance towards paracetamol was evaluated using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The experimental results indicate that the as-synthesized Pd nanoparticles are relatively uniform in size (5-10 nm) without large aggregation and uniformly distributed in the carbon matrix with the overall Pd content of 28.77 wt% in Pd/GO. Compared with the GO modified electrode, the Pd/GO modified electrode shows a better electrocatalytic activity to the oxidation of paracetamol with lower oxidation potential and larger peak current, so the Pd/GO nanocomposite can be used as an enhanced sensing platform for the electrochemical determination of paracetamol. The kinetic parameters of the paracetamol electro-oxidation at Pd/GO electrode were studied in detail, and the determination conditions were optimized. Under the optimal conditions, the oxidation peak current is linear to the paracetamol concentration in the ranges of 0.005-0.5 μM and 0.5-80.0 μM with a detection limit of 2.2 nM. Based on the high sensitivity and good selectivity of the Pd/GO modified electrode, the proposed method was successfully applied to the determination of paracetamol in commercial tablets and human urines, and the satisfactory results confirm the applicability of this sensor in practical analysis.
© 2013 Published by Elsevier B.V.

Entities:  

Keywords:  Electrochemical sensor; Graphene oxide; Paracetamol; Pd nanoparticles

Mesh:

Substances:

Year:  2013        PMID: 24315879     DOI: 10.1016/j.bios.2013.11.001

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

1.  Morphology Effect of Bismuth Vanadate on Electrochemical Sensing for the Detection of Paracetamol.

Authors:  Ying Liu; Xiaocui Xu; Churong Ma; Feng Zhao; Kai Chen
Journal:  Nanomaterials (Basel)       Date:  2022-04-01       Impact factor: 5.076

2.  Pulicaria glutinosa extract: a toolbox to synthesize highly reduced graphene oxide-silver nanocomposites.

Authors:  Abdulhadi H Al-Marri; Mujeeb Khan; Merajuddin Khan; Syed F Adil; Abdulrahman Al-Warthan; Hamad Z Alkhathlan; Wolfgang Tremel; Joselito P Labis; Mohammed Rafiq H Siddiqui; Muhammad N Tahir
Journal:  Int J Mol Sci       Date:  2015-01-05       Impact factor: 5.923

Review 3.  Reviews of the toxicity behavior of five potential engineered nanomaterials (ENMs) into the aquatic ecosystem.

Authors:  Shanaz Jahan; Ismail Bin Yusoff; Yatimah Binti Alias; Ahmad Farid Bin Abu Bakar
Journal:  Toxicol Rep       Date:  2017-04-04

4.  Voltammetric determination of paracetamol in tablet formulation using Fe (III) doped zeolite-graphite composite modified GCE.

Authors:  Meareg Amare
Journal:  Heliyon       Date:  2019-05-10

5.  Determination of Paracetamol on Electrochemically Reduced Graphene Oxide-Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry.

Authors:  Zandile D Leve; Nazeem Jahed; Nelia A Sanga; Emmanuel I Iwuoha; Keagan Pokpas
Journal:  Sensors (Basel)       Date:  2022-08-03       Impact factor: 3.847

6.  A Novel Electrochemical Nanosensor for the Simultaneous Sensing of Two Toxic Food Dyes.

Authors:  Afzal Shah
Journal:  ACS Omega       Date:  2020-03-13

7.  Disposable Nafion-Coated Single-Walled Carbon Nanotube Test Strip for Electrochemical Quantitative Determination of Acetaminophen in a Finger-Prick Whole Blood Sample.

Authors:  Niklas Wester; Bjørn F Mikladal; Ilkka Varjos; Antti Peltonen; Eija Kalso; Tuomas Lilius; Tomi Laurila; Jari Koskinen
Journal:  Anal Chem       Date:  2020-09-11       Impact factor: 6.986

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.