Literature DB >> 24307717

Reproducibility of macular ganglion cell-inner plexiform layer thickness measurement with cirrus HD-OCT in normal, hypertensive and glaucomatous eyes.

Marlène Francoz1, Jean-Rémi Fenolland, Jean-Marie Giraud, Hussam El Chehab, Damien Sendon, Franck May, Jean-Paul Renard.   

Abstract

AIM: To evaluate the intraobserver and interobserver reproducibility of macular retinal ganglion cell-inner plexiform layer (GC-IPL) thickness measurement by automated detection on Optical Coherence Tomography (OCT) images in normal, hypertensive (ocular hypertensive (OHT)) and glaucomatous eyes.
METHODS: A total of 138 eyes were enrolled in three groups: 69 normal, 35 OHT and 34 primary open-angle glaucoma eyes. All patients underwent a complete ocular examination, 24-2 automated perimetry, biometry and pachymetry. Macular imaging was performed in each eye using the Cirrus HD-OCT 4000 with software V.6.0. (Carl Zeiss Meditec, Dublin, California, USA) three times on the same day by each of two observers, and the GC analysis (GCA) algorithm provided parameters expressed as average, minimum and six sectoral GC-IPL thicknesses. Reproducibility was assessed by intraclass correlation coefficient (ICC), coefficient of variation (CV) and test-retest variability (TRTV) calculated as 1.96 times the SD.
RESULTS: Mean GC-IPL thickness was 82.27 ± 7.37 μm, 76.84 ± 7.01 μm and 66.16 ± 11.16 μm in normal, OHT and glaucoma groups, respectively. GC-IPL thickness was significantly lower in glaucomatous eyes than in normal and OHT eyes (p<0.0001 for all parameters). In all groups, ICC ranged from 96.4 to 99.9% and 92.5 to 99.8%, CV ranged from 0.41 to 2.24% and 0.55 to 1.67%, and TRTV ranged from 0.61 to 2.64 μm and 0.83 to 2.22 μm for intraobserver and interobserver reproducibility, respectively.
CONCLUSIONS: To the best of our knowledge, this is the first study of GCA algorithm reproducibility in normal, OHT and glaucomatous eyes. The reproducibility of GC-IPL thickness measurements using the Cirrus HD-OCT GCA algorithm was found to be highly satisfactory. GC-IPL thickness may be a promising new OCT parameter for analysis of ganglion cell damage in glaucoma.

Entities:  

Keywords:  Diagnostic Tests/Investigation; Glaucoma; Imaging; Macula; Retina

Mesh:

Year:  2013        PMID: 24307717     DOI: 10.1136/bjophthalmol-2012-302242

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  22 in total

1.  Intra- and inter-visit reproducibility of ganglion cell-inner plexiform layer measurements using handheld optical coherence tomography in children with optic pathway gliomas.

Authors:  Robert A Avery; Avital Cnaan; Joel S Schuman; Chieh-Li Chen; Natalie C Glaug; Roger J Packer; Graham E Quinn; Hiroshi Ishikawa
Journal:  Am J Ophthalmol       Date:  2014-07-25       Impact factor: 5.258

2.  Repeatability of ganglion cell-inner plexiform layer thickness measurements using spectral-domain OCT in branch retinal vein occlusion.

Authors:  Yeon Hee Lee; Min-Su Kim; Seung Il Ahn; Hye Jin Park; Kyung Sup Shin; Jung-Yeul Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-06-11       Impact factor: 3.117

3.  Evaluation of the retinal nerve fibre layer and ganglion cell complex thickness in pituitary macroadenomas without optic chiasmal compression.

Authors:  G Cennamo; R S Auriemma; D Cardone; L F S Grasso; N Velotti; C Simeoli; C Di Somma; R Pivonello; A Colao; G de Crecchio
Journal:  Eye (Lond)       Date:  2015-03-27       Impact factor: 3.775

4.  Evaluating glaucoma damage: emerging imaging technologies.

Authors:  Tigran Kostanyan; Gadi Wollstein; Joel S Schuman
Journal:  Expert Rev Ophthalmol       Date:  2015-02-09

5.  Longitudinal Macular Structure-Function Relationships in Glaucoma and Their Sources of Variability.

Authors:  Kouros Nouri-Mahdavi; Nima Fatehi; Joseph Caprioli
Journal:  Am J Ophthalmol       Date:  2019-05-10       Impact factor: 5.258

Review 6.  New developments in optical coherence tomography.

Authors:  Tigran Kostanyan; Gadi Wollstein; Joel S Schuman
Journal:  Curr Opin Ophthalmol       Date:  2015-03       Impact factor: 3.761

7.  Changes in Schlemm's canal, trabecular meshwork, and relevant parameters in the early stage after SMILE of myopia patients.

Authors:  Dan-Dan Yang; Zhi-Qi Chen; Wei Chen; He Yin; Jing-Kai Peng; Jun-Ming Wang
Journal:  Int J Ophthalmol       Date:  2022-02-18       Impact factor: 1.779

Review 8.  Macular imaging with optical coherence tomography in glaucoma.

Authors:  Vahid Mohammadzadeh; Nima Fatehi; Adeleh Yarmohammadi; Ji Woong Lee; Farideh Sharifipour; Ramin Daneshvar; Joseph Caprioli; Kouros Nouri-Mahdavi
Journal:  Surv Ophthalmol       Date:  2020-03-19       Impact factor: 6.048

9.  Longitudinal analysis of retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in ethambutol-induced optic neuropathy.

Authors:  Jinu Han; Min Kwang Byun; Junwon Lee; So Young Han; Jong Bok Lee; Sueng-Han Han
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-09-07       Impact factor: 3.117

Review 10.  Advances in ophthalmic structural and functional measures in multiple sclerosis: do the potential ocular biomarkers meet the unmet needs?

Authors:  Hong Jiang; Silvia Delgado; Jianhua Wang
Journal:  Curr Opin Neurol       Date:  2021-02-01       Impact factor: 6.283

View more