Literature DB >> 24307367

An iron impurity in multiwalled carbon nanotube complexes with chitosan that biomimics the heme-peroxidase function.

Prakasam Gayathri1, Annamalai Senthil Kumar.   

Abstract

A new biomimetic functional system having an impure multiwalled carbon nanotube (MWCNT-Fe)-chitosan biopolymer (H2N-CHIT) chemically modified glassy carbon electrode (GCE/[MWCNT-Fe:H2N-CHIT]) has been developed and demonstrated efficient hydrogen peroxide electrocatalytic and electrochemical sensing applications in pH 7 phosphate buffer solution (PBS). The hybrid system showed a stable and well-defined surface confined redox peak at an apparent electrode potential, E°'=-0.22 V versus Ag/AgCl with surface excess value 13.63 nmol cm(-2). Physicochemical characterizations of the hybrid by using FESEM, TEM, Raman spectroscopy, FTIR, and various control electrochemical experiments revealed that the iron impurity in the MWCNT interacted with the amino functional group of the chitosan polymer and thereby formed an unique complex-like structure ([MWCNT-Fe(III/II):NH2-CHIT]), similar to heme peroxidase with a central Fe(III/II)-redox-active site. The biomimetic system followed Michaelis-Menten-type reaction kinetics for the H2O2 reduction reaction with a K(M) value of 0.23 mM. At pH 7, amperometric i-t sensing and flow-injection analysis of H2O2 on the biomimetic system showed calibration plots in windows 5-500 and 50-2500 μM, with detection-limit values of 2.3 and 9.7 μM, respectively. Unlike most of the previously reported systems that undergo serious interferences in physiological pH, the biomimetic system displayed a remarkable tolerance to other co-existing interferants (such as cysteine, ascorbic acid, uric acid, nitrate, and nitrite), at a H2O2 detection potential similar to the peroxidase enzyme. The ability of the biosensor system to perform routine analyses was demonstrated by the detection of H2O2 present in simulated milk and clinical and cosmetic samples with appreciable recovery values.
Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  biopolymers; carbon; electrochemistry; heme; nanotubes; sensors

Mesh:

Substances:

Year:  2013        PMID: 24307367     DOI: 10.1002/chem.201303075

Source DB:  PubMed          Journal:  Chemistry        ISSN: 0947-6539            Impact factor:   5.236


  4 in total

1.  In Situ Immobilized Sesamol-Quinone/Carbon Nanoblack-Based Electrochemical Redox Platform for Efficient Bioelectrocatalytic and Immunosensor Applications.

Authors:  Mansi Gandhi; Desikan Rajagopal; Sampath Parthasarathy; Sudhakaran Raja; Sheng-Tung Huang; Annamalai Senthil Kumar
Journal:  ACS Omega       Date:  2018-09-07

2.  Axial Coordination Site-Turned Surface Confinement, Electron Transfer, and Bio-Electrocatalytic Applications of a Hemin Complex on Graphitic Carbon Nanomaterial-Modified Electrodes.

Authors:  Khairunnisa Amreen; Annamalai Senthil Kumar; Veerappan Mani; Sheng-Tung Huang
Journal:  ACS Omega       Date:  2018-05-21

3.  Simple and Precise Quantification of Iron Catalyst Content in Carbon Nanotubes Using UV/Visible Spectroscopy.

Authors:  Elsye Agustina; Jeungchoon Goak; Suntae Lee; Youngho Seo; Jun-Young Park; Naesung Lee
Journal:  ChemistryOpen       Date:  2015-06-29       Impact factor: 2.911

4.  Calcium Alginate Beads with Entrapped Iron Oxide Magnetic Nanoparticles Functionalized with Methionine-A Versatile Adsorbent for Arsenic Removal.

Authors:  Surbhi Lilhare; Sunitha B Mathew; Ajaya K Singh; Sónia A C Carabineiro
Journal:  Nanomaterials (Basel)       Date:  2021-05-20       Impact factor: 5.076

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.