Literature DB >> 24306083

The utility of stroke volume variability as a predictor of fluid responsiveness in critically ill children: a pilot study.

Jack R L McLean1, David P Inwald2.   

Abstract

Entities:  

Mesh:

Year:  2013        PMID: 24306083      PMCID: PMC3905190          DOI: 10.1007/s00134-013-3171-x

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


× No keyword cloud information.
Dear Editor, Predicting the response to fluid bolus therapy in critically ill children is difficult [1]. However, rapid bolus fluid resuscitation is integral to the management of children presenting with severe sepsis [2]. Bolus was compared with maintenance fluid in a relatively recent large randomized controlled trial carried out in in the developing world (the Fluid Expansion As Supportive Therapy—FEAST) that involved a large cohort of African children with severe infection [3]. The surprising result of FEAST was that bolus fluid was associated with a 30 % increase in mortality. Methods to predict fluid responsiveness in children requiring paediatric intensive care unit (PICU) admission might therefore be extremely useful. Previous paediatric studies have highlighted the utility of Doppler-based methods [4] and have demonstrated that stroke volume variability (SVV) predicts fluid responsiveness [5]. However, data in a PICU setting are currently limited. The aim of our pilot study was to evaluate the utility of SVV as a predictor of fluid responsiveness in a PICU. We studied a group of 13 mechanically ventilated children, aged 2 months to 14 years, who were given fluid boluses in the PICU at St Mary’s Hospital, London, from 18 March 2013 to 13 May 2013. Exclusion criteria were high-frequency oscillatory ventilation, arrhythmia and left to right shunt. The study design was reviewed and approved by Brent Research Ethics Committee. Written informed consent was obtained from an individual with parental responsibility. Heart rate and blood pressure were continuously monitored on an Intellivue MP70 patient monitor (Philips Healthcare, Guildford, UK). The data collected on these parameters were subsequently analysed as the mean of three readings each timed 1 min apart. Stroke volume index (SVI) and SVV were measured non-invasively at the aortic valve using suprasternal Doppler (USCOM Ltd., Sydney, Australia). SVV is calculated automatically as: (SVmax − SVmin)/[(SVmax + SVmin)] × 100 from a 7-s data window. Doppler traces were recorded in triplicate, and the values of SVI and SVV used in the analysis were the mean of three measurements. After the initial data collection immediately prior to the administration of fluid bolus, 10 ml/kg fluid bolus was administered. Data were collected again immediately post fluid bolus. Patients were defined as either responsive or non-responsive to each individual fluid bolus, with responsive defined as an increase in SVI of at least 10 %. Data on a total of 26 fluid boluses were analysed. In 11 boluses, patients were classified as responsive and in 15 non-responsive. Static haemodynamic parameters did not differ significantly between the two groups, and ventilation and inotrope use was unchanged. SVV differed significantly between the responsive (median 16.67 %, range 12.35–19.17 %) and non-responsive groups (11.53 %, range 9.82–14.17 %) (p = 0.01) (Fig. 1). The receiver operating characteristic curve analysis for pre-bolus SVV to predict a >10 % rise in SVI post-bolus found an area under the curve of 0.797 (95 % confidence interval 0.623–0.971, p = 0.01). The Youden index calculations identified an optimal cutoff for SVV of 16.5 % (sensitivity 54.5 %, specificity 93.3 %). This cutoff has a positive likelihood ratio of 8.18 and a negative likelihood ratio of 0.49.
Fig. 1

Stroke volume variability (SVV) in responsive (increase in SVI of >10 %) and non-responsive patients following administration of fluid bolus. Black horizontal lines indicate median values for each group, red horizontal line indicates the 16.5 % cutoff identified

Stroke volume variability (SVV) in responsive (increase in SVI of >10 %) and non-responsive patients following administration of fluid bolus. Black horizontal lines indicate median values for each group, red horizontal line indicates the 16.5 % cutoff identified Taken together, these results suggest that SVV has the potential to predict fluid responsiveness in mechanically ventilated children in the PICU. The small sample size of our pilot study limits generalizability, and further work is required to confirm and extend these findings.
  4 in total

1.  Mortality after fluid bolus in African children with severe infection.

Authors:  Kathryn Maitland; Sarah Kiguli; Robert O Opoka; Charles Engoru; Peter Olupot-Olupot; Samuel O Akech; Richard Nyeko; George Mtove; Hugh Reyburn; Trudie Lang; Bernadette Brent; Jennifer A Evans; James K Tibenderana; Jane Crawley; Elizabeth C Russell; Michael Levin; Abdel G Babiker; Diana M Gibb
Journal:  N Engl J Med       Date:  2011-05-26       Impact factor: 91.245

2.  Clinicians' abilities to estimate cardiac index in ventilated children and infants.

Authors:  S M Tibby; M Hatherill; M J Marsh; I A Murdoch
Journal:  Arch Dis Child       Date:  1997-12       Impact factor: 3.791

3.  Clinical practice parameters for hemodynamic support of pediatric and neonatal septic shock: 2007 update from the American College of Critical Care Medicine.

Authors:  Joe Brierley; Joseph A Carcillo; Karen Choong; Tim Cornell; Allan Decaen; Andreas Deymann; Allan Doctor; Alan Davis; John Duff; Marc-Andre Dugas; Alan Duncan; Barry Evans; Jonathan Feldman; Kathryn Felmet; Gene Fisher; Lorry Frankel; Howard Jeffries; Bruce Greenwald; Juan Gutierrez; Mark Hall; Yong Y Han; James Hanson; Jan Hazelzet; Lynn Hernan; Jane Kiff; Niranjan Kissoon; Alexander Kon; Jose Irazuzta; Jose Irazusta; John Lin; Angie Lorts; Michelle Mariscalco; Renuka Mehta; Simon Nadel; Trung Nguyen; Carol Nicholson; Mark Peters; Regina Okhuysen-Cawley; Tom Poulton; Monica Relves; Agustin Rodriguez; Ranna Rozenfeld; Eduardo Schnitzler; Tom Shanley; Saraswati Kache; Sara Skache; Peter Skippen; Adalberto Torres; Bettina von Dessauer; Jacki Weingarten; Timothy Yeh; Arno Zaritsky; Bonnie Stojadinovic; Jerry Zimmerman; Aaron Zuckerberg
Journal:  Crit Care Med       Date:  2009-02       Impact factor: 7.598

4.  Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children.

Authors:  Philippe Durand; Laurent Chevret; Sandrine Essouri; Vincent Haas; Denis Devictor
Journal:  Intensive Care Med       Date:  2008-02-08       Impact factor: 17.440

  4 in total
  2 in total

Review 1.  Does stroke volume variation predict fluid responsiveness in children: A systematic review and meta-analysis.

Authors:  Ling Yi; Zhongqiang Liu; Lina Qiao; Chaomin Wan; Dezhi Mu
Journal:  PLoS One       Date:  2017-05-12       Impact factor: 3.240

2.  Dynamic variables predict fluid responsiveness in pre-school and school children undergoing neurosurgery: a prospective observational study.

Authors:  Lin-Lin Song; Zhi-Yu Geng; Wei Ma; Ya-Fei Liu; Dong-Xin Wang
Journal:  Transl Pediatr       Date:  2021-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.