Literature DB >> 24305987

Upside down use of Gore Excluder or Cook Zenith legs.

Takatoshi Higashigawa1, Noriyuki Kato, Takashi Hashimoto, Mikito Inouchi, Shuji Chino, Naoki Yamamoto, Uhito Yuasa, Toshiya Tokui, Yoshihiro Noda, Kensuke Oue, Manabu Okabe.   

Abstract

PURPOSE: Endovascular aneurysm repair is becoming increasingly popular. This technical note describes the usefulness of the upside-down technique of Gore Excluder or Cook Zenith legs.
METHODS: Four patients with iliac or abdominal aortic aneurysms were treated. Three patients with isolated iliac artery aneurysms and one patient with an abdominal aortic aneurysm, in which the neck diameters were unfit for commercially available stent-grafts, were treated using an Excluder or a Zenith leg in an upside-down technique.
RESULTS: The aneurysms were completely excluded and no endoleak occurred. There were no serious adverse events.
CONCLUSIONS: The upside-down technique using an Excluder leg or a Zenith leg is both feasible and effective.

Entities:  

Mesh:

Year:  2013        PMID: 24305987     DOI: 10.1007/s00270-013-0802-0

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  1 in total