Literature DB >> 24304369

Ni/CdS bifunctional Ti@TiO2 core-shell nanowire electrode for high-performance nonenzymatic glucose sensing.

Chunyan Guo1, Huanhuan Huo, Xu Han, Cailing Xu, Hulin Li.   

Abstract

In this work, a Ni/CdS bifunctional Ti@TiO2 core-shell nanowire electrode with excellent electrochemical sensing property was successfully constructed through a hydrothermal and electrodeposition method. Field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) were employed to confirm the synthesis and characterize the morphology of the as-prepared samples. The results revealed that the CdS layer between Ni and TiO2 plays an important role in the uniform nucleation and the following growth of highly dispersive Ni nanoparticle on the Ti@TiO2 core-shell nanowire surface. The bifunctional nanostructured electrode was applied to construct an electrochemical nonenzymatic sensor for the reliable detection of glucose. Under optimized conditions, this nonenzymatic glucose sensor displayed a high sensitivity up to 1136.67 μA mM(-1) cm(-2), a wider liner range of 0.005-12 mM, and a lower detection limit of 0.35 μM for glucose oxidation. The high dispersity of Ni nanoparticles, combined with the anti-poisoning faculty against the intermediate derived from the self-cleaning ability of CdS under the photoexcitation, was considered to be responsible for these enhanced electrochemical performances. Importantly, favorable reproducibility and long-term performance were also obtained thanks to the robust frameworks. All these results indicate this novel electrode is a promising candidate for nonenzymatic glucose sensing.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24304369     DOI: 10.1021/ac4034467

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Nitrogen-containing three-dimensional biomass porous carbon materials as an efficient enzymatic biosensing platform for glucose sensing.

Authors:  Baixi Shan; Yanhua Ji; Youbao Zhong; Lai Chen; Shanshan Li; Jie Zhang; Liling Chen; Xuan Liu; Yuan Chen; Nan Yan; Yonggui Song
Journal:  RSC Adv       Date:  2019-08-15       Impact factor: 4.036

Review 2.  Carbon nanotubes in electrochemical, colorimetric, and fluorimetric immunosensors and immunoassays: a review.

Authors:  Hualin Yang; Wentao Xu; Xiongyan Liang; Yuying Yang; Yu Zhou
Journal:  Mikrochim Acta       Date:  2020-03-09       Impact factor: 5.833

3.  Rational design of binder-free noble metal/metal oxide arrays with nanocauliflower structure for wide linear range nonenzymatic glucose detection.

Authors:  Zhenzhen Li; Yanmei Xin; Zhonghai Zhang; Hongjun Wu; Peng Wang
Journal:  Sci Rep       Date:  2015-06-12       Impact factor: 4.379

Review 4.  Electrochemical sensors and biosensors based on nanomaterials and nanostructures.

Authors:  Chengzhou Zhu; Guohai Yang; He Li; Dan Du; Yuehe Lin
Journal:  Anal Chem       Date:  2014-12-19       Impact factor: 6.986

5.  Constructing a TiO2/PDA core/shell nanorod array electrode as a highly sensitive and stable photoelectrochemical glucose biosensor.

Authors:  Wei Xu; Wenke Yang; Hongkai Guo; Lianyuan Ge; Jinchun Tu; Chao Zhen
Journal:  RSC Adv       Date:  2020-03-10       Impact factor: 3.361

6.  Sensitive electrochemical nonenzymatic glucose sensing based on anodized CuO nanowires on three-dimensional porous copper foam.

Authors:  Zhenzhen Li; Yan Chen; Yanmei Xin; Zhonghai Zhang
Journal:  Sci Rep       Date:  2015-11-02       Impact factor: 4.379

7.  Fabrication of porous NiMn2O4 nanosheet arrays on nickel foam as an advanced sensor material for non-enzymatic glucose detection.

Authors:  Jie Zhang; Yudong Sun; Xianchun Li; Jiasheng Xu
Journal:  Sci Rep       Date:  2019-12-02       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.