| Literature DB >> 24302807 |
J A Kareparamban1, P H Nikam, A P Jadhav, V J Kadam.
Abstract
A high-performance liquid chromatography method was developed for the estimation of ferulic acid from asafoetida and a polyherbal preparation. The separation was carried out on HiQSil ODS C-18 column with a mobile phase of acetonitrile: 10% acetic acid (20:80 v/v). The developed method was validated as per International Conference of Harmonization guidelines for various parameters such as accuracy, precision, linearity, limit of detection, limit of quantification and specificity; and found to be reliable. Linear regression analysis showed a good corelation between peak area and concentration with a corelation coefficient r(2)=0.996 in the range 200-7000 ng/ml. The developed method can be utilized for standardization of herbal formulation comprising asafoetida.Entities:
Keywords: High-performance liquid chromatograhy; asafoetida; ferulic acid; polyherbal formulations.
Year: 2013 PMID: 24302807 PMCID: PMC3831734 DOI: 10.4103/0250-474X.119826
Source DB: PubMed Journal: Indian J Pharm Sci ISSN: 0250-474X Impact factor: 0.975
Fig. 1HPLC chromatograms of standard, asafoetida methanol extract, and polyherbal preparation.
Chromatograms showing. (a) ferulic acid (b) methanol extract of asafoetida and (c) polyherbal preparation.
ACCURACY AS RECOVERY
STATISTICAL VALIDATION OF RECOVERY DATA
INTRADAY AND INTERDAY PRECISION OF HPLC METHOD