Literature DB >> 24301799

A dual enzyme functionalized nanostructured thulium oxide based interface for biomedical application.

Jay Singh1, Appan Roychoudhury, Manish Srivastava, Pratima R Solanki, Dong Won Lee, Seung Hee Lee, B D Malhotra.   

Abstract

In this paper, we present results of the studies related to fabrication of a rare earth metal oxide based efficient biosensor using an interface based on hydrothermally prepared nanostructured thulium oxide (n-Tm2O3). A colloidal solution of prepared nanorods has been electrophoretically deposited (EPD) onto an indium-tin-oxide (ITO) glass substrate. The n-Tm2O3 nanorods are found to provide improved sensing characteristics to the electrode interface in terms of electroactive surface area, diffusion coefficient, charge transfer rate constant and electron transfer kinetics. The structural and morphological studies of n-Tm2O3 nanorods have been carried out by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR) spectroscopic techniques. This interfacial platform has been used for fabrication of a total cholesterol biosensor by immobilizing cholesterol esterase (ChEt) and cholesterol oxidase (ChOx) onto a Tm2O3 nanostructured surface. The results of response studies of the fabricated ChEt-ChOx/n-Tm2O3/ITO bioelectrode show a broad linear range of 8-400 mg dL(-1), detection limit of 19.78 mg (dL cm(-2))(-1), and high sensitivity of 0.9245 μA (mg per dL cm(-2))(-1) with a response time of 40 s. Further, this bioelectrode has been utilized for estimation of total cholesterol with negligible interference (3%) from analytes present in human serum samples. The utilization of this n-Tm2O3 modified electrode for enzyme-based biosensor analysis offers an efficient strategy and a novel interface for application of the rare earth metal oxide materials in the field of electrochemical sensors and bioelectronic devices.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24301799     DOI: 10.1039/c3nr05043b

Source DB:  PubMed          Journal:  Nanoscale        ISSN: 2040-3364            Impact factor:   7.790


  3 in total

Review 1.  Electrochemical oxidation of cholesterol.

Authors:  Jacek W Morzycki; Andrzej Sobkowiak
Journal:  Beilstein J Org Chem       Date:  2015-03-25       Impact factor: 2.883

Review 2.  Electrochemical sensors and biosensors based on nanomaterials and nanostructures.

Authors:  Chengzhou Zhu; Guohai Yang; He Li; Dan Du; Yuehe Lin
Journal:  Anal Chem       Date:  2014-12-19       Impact factor: 6.986

3.  Influence of NH3 plasma and Ti doping on pH-sensitive CeO2 electrolyte-insulator-semiconductor biosensors.

Authors:  Chyuan-Haur Kao; Che-Wei Chang; Yu Tzu Chen; Wei Ming Su; Chien Cheng Lu; Chan-Yu Lin; Hsiang Chen
Journal:  Sci Rep       Date:  2017-05-25       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.