Literature DB >> 24299654

The Effect of Implant Angulation on the Transfer Accuracy of External-Connection Implants.

Marzieh Alikhasi1, Hakimeh Siadat2, Susan Rahimian3.   

Abstract

BACKGROUND: Accurate recording of implant location is required in every implant-supported prostheses. Implant angulation, which is inevitable in various clinical situations, could affect the impression accuracy.
PURPOSE: The purpose of this in vitro study was to compare the transfer accuracy of straight and tilted implants of All-on-4 protocol with implant or abutment level impression making and different techniques of direct and indirect.
MATERIALS AND METHODS: One reference model of edentulous maxilla with four external connection implants (Brånemark) inserted according to All-on-4 protocol was made. Forty impressions of this model were made at implant (groups 1 and 2) or abutment (groups 3 and 4) levels with different techniques of direct or indirect, respectively. Impressions were poured with type IV dental stone. Coordinate measuring machine was used to record x, y, and z coordinates and also angular dislocation of implants. These measurements were compared with the equals calculated on the reference model. Data were analyzed with univariate analysis of variance and t-test at α = 0.05.
RESULTS: The results showed that abutment level impression making (groups 3 and 4), either with direct or indirect technique, produced the same results for straight and tilted implants of Δr variable (p > .05), though in implant level groups (groups 1 and 2), it was statistically significant (p < .05). However, only implant level impression making with direct technique (group 1) had the same results of angular accuracy for straight and tilted implants.
CONCLUSION: Impression technique (direct or indirect) had significant effect on the impression accuracy of tilted implants, and direct technique produced less inaccuracy. Also, abutment level impressions showed more accuracy than implant level impressions.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  abutment; angled abutment; implant; impression; tilted implant

Mesh:

Substances:

Year:  2013        PMID: 24299654     DOI: 10.1111/cid.12185

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  6 in total

1.  Effects of Immediate and Delayed Loading on the Outcomes of All-on-4 Treatment: A Prospective Study.

Authors:  Hossein Najafi; Hakimeh Siadat; Solmaz Akbari; Amirreza Rokn
Journal:  J Dent (Tehran)       Date:  2016-11

2.  A Comparison of implant impression precision: Different materials and techniques.

Authors:  Mahtab Tabesh; Marzieh Alikhasi; Hakimeh Siadat
Journal:  J Clin Exp Dent       Date:  2018-02-01

3.  Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type.

Authors:  Marzieh Alikhasi; Hakime Siadat; Alireza Nasirpour; Mahya Hasanzade
Journal:  Int J Dent       Date:  2018-06-04

4.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

5.  Influence of Implant Impression Methods, Polymer Materials, and Implant Angulation on the Accuracy of Dental Models.

Authors:  Daniela Djurovic Koprivica; Tatjana Puskar; Igor Budak; Mario Sokac; Milica Jeremic Knezevic; Aleksandra Maletin; Bojana Milekic; Djordje Vukelic
Journal:  Polymers (Basel)       Date:  2022-07-11       Impact factor: 4.967

6.  Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions.

Authors:  Hakimeh Siadat; Zeinab Saeidi; Marzieh Alikhasi; Somayeh Zeighami
Journal:  J Clin Exp Dent       Date:  2018-11-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.