Literature DB >> 24297030

Numerical and experimental analysis of unidirectional meander-line coil electromagnetic acoustic transducers.

Shujuan Wang, Riliang Su, Xiaoyang Chen, Lei Kang, Guofu Zhai.   

Abstract

The elastic waves generated by traditional meander-line coil electromagnetic acoustic transducers (EMATs) propagate in two directions, overlapping the echo signals from defects with the same distances, and the defect echo signal is hard to distinguish from the edge-reflected signal when the EMATs are near the edge of a specimen. In this paper, a unidirectional EMAT with two meander-line coils is proposed. A finite element model is used to simulate the directivity of the Rayleigh and shear vertical waves generated by these EMATs. Six transducers are fabricated using the printed circuit technique. The unidirectional Rayleigh wave and shear vertical wave are tested, and the results agree well with the simulation.

Year:  2013        PMID: 24297030     DOI: 10.1109/TUFFC.2013.2864

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  1 in total

1.  An Improved Design of the Spiral-Coil EMAT for Enhancing the Signal Amplitude.

Authors:  Xiaojuan Jia; Qi Ouyang; Xinglan Zhang
Journal:  Sensors (Basel)       Date:  2017-05-12       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.