Literature DB >> 24296770

Pneumothorax occurring after nasogastric tube removal.

Vishesh Paul1, Amith Shenoy, Yizhak Kupfer, Sidney Tessler.   

Abstract

An 85-year-old woman with failure to thrive due to poor oral intake was admitted owing to dehydration. A nasogastric (NG) tube was inserted for the initiation of enteral feedings. The tube position was confirmed by gastric auscultation after insufflating air through the tube. A chest X-ray revealed that the NG tube traversed the right main stem bronchus with its tip ending in the right costophrenic angle adjacent to the pleura. No pneumothorax was identified. The tube was removed and a short while later the patient developed mild chest discomfort. A repeat chest X-ray revealed significant pneumothorax on the right side. She was treated conservatively with 100% oxygen with successful resolution of the pneumothorax.

Entities:  

Mesh:

Year:  2013        PMID: 24296770      PMCID: PMC3863106          DOI: 10.1136/bcr-2013-010419

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  4 in total

1.  Flexible nasogastric feeding tube tip malposition immediately after placement.

Authors:  R Benya; S Langer; S Mobarhan
Journal:  JPEN J Parenter Enteral Nutr       Date:  1990 Jan-Feb       Impact factor: 4.016

2.  Thoracic complications of nasogastric tube: review of safe practice.

Authors:  Jain Bhaskara Pillai; Annette Vegas; Stephanie Brister
Journal:  Interact Cardiovasc Thorac Surg       Date:  2005-06-21

3.  Enhancing patient safety during feeding-tube insertion: a review of more than 2,000 insertions.

Authors:  Rachel Sorokin; Jonathan E Gottlieb
Journal:  JPEN J Parenter Enteral Nutr       Date:  2006 Sep-Oct       Impact factor: 4.016

4.  Clinical costs of feeding tube placement.

Authors:  Jose Eduardo de Aguilar-Nascimento; Kenneth A Kudsk
Journal:  JPEN J Parenter Enteral Nutr       Date:  2007 Jul-Aug       Impact factor: 4.016

  4 in total
  3 in total

1.  Rare and unexpected complication after a malpositioned nasogastric tube in a neonate.

Authors:  Osama Hosheh; Liz Mckechnie
Journal:  BMJ Case Rep       Date:  2018-04-11

2.  Hemothorax Following Traumatic Dobhoff Tube Insertion.

Authors:  Lindsey M Shain; Leslie McHale; Taha Ahmed
Journal:  Cureus       Date:  2021-02-03

3.  Deadly pressure pneumothorax after withdrawal of misplaced feeding tube: a case report.

Authors:  Erik Nygaard Andresen; Martin Frydland; Lotte Usinger
Journal:  J Med Case Rep       Date:  2016-02-03
  3 in total