Literature DB >> 24296597

Negative pressure wound therapy and external fixation device: a simple way to seal the dressing.

Antonio Bulla1, Francesco Farace, André-Pierre Uzel, Vincent Casoli.   

Abstract

Negative pressure therapy is widely applied to treat lower limb trauma. However, sealing a negative pressure dressing in the presence of an external fixation device may be difficult and time consuming. Therefore, screws, pins, wires, etc, may preclude the vacuum, preventing the plastic drape to perfectly adhere to the foam. To maintain the vacuum, we tried to prevent air leaking around the screws putting bone wax at the junction between the pins and the plastic drape. This solution, in our hands, avoids air leakage and helps maintain vacuum in a fast and inexpensive way.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24296597     DOI: 10.1097/BOT.0000000000000013

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  6 in total

1.  Effect of vacuum sealing drainage in osteofascial compartment syndrome.

Authors:  Weihua Li; Lei Ji; Weidong Tao
Journal:  Int J Clin Exp Med       Date:  2015-09-15

2.  Letter to the Editor: Negative Pressure Wound Therapy in Grade IIIB Tibial Fractures: Fewer Infections and Fewer Flap Procedures?

Authors:  Sandeep Mehrotra; Sunil Anand
Journal:  Clin Orthop Relat Res       Date:  2016-07-20       Impact factor: 4.176

3.  Vacuum sealing drainage therapy in the presence of an external fixation device: A case report.

Authors:  Dahui Sun; Weina Ju; Tiejun Wang; Tiecheng Yu; Baochang Qi
Journal:  Medicine (Baltimore)       Date:  2016-11       Impact factor: 1.889

4.  A filled chocolates technique to seal negative-pressure wound therapy around external fixation devices: a randomized controlled trial.

Authors:  Wei Fan; Fushan Hou; Kun Xi; Chen Hao; Xiangdong Lu; Bin Zhao
Journal:  J Orthop Surg Res       Date:  2021-10-12       Impact factor: 2.359

5.  [VSD - A Good Idea for the Management of Surgical Infection].

Authors:  Chaoyang Liang
Journal:  Zhongguo Fei Ai Za Zhi       Date:  2018-04-20

6.  Clinical experience of biliary T tube of immobilization of peri-pin membrane in tibial Gustilo III fracture treated with vacuum sealant drainage combined with an external fixator.

Authors:  Hui Ye; Shufeng Lin; Junfeng Zhu; Lifeng Jiang
Journal:  Medicine (Baltimore)       Date:  2020-10-23       Impact factor: 1.817

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.