Literature DB >> 24293589

Clinical results, radiological findings and survival of a proximally hydroxyapatite-coated hip ABG II stem at a minimum of ten years' follow-up: results of a consecutive multicentre study of 1148 hips in 1053 patients.

J-A Epinette1, G Asencio, J Essig, B Llagonne, C Nourissat.   

Abstract

We report a multicentre prospective consecutive study assessing the long-term outcome of the proximally hydroxyapatite (HA)-coated ABG II monobloc femoral component in a series of 1148 hips in 1053 patients with a mean age at surgery of 64.77 years (22 to 80) at a mean follow-up of 10.84 years (10 to 15.25). At latest follow-up, the mean total Harris hip score was 94.7 points (sd; 6.87; 49 to 100), and the mean Merle d'Aubigné-Postel score was 17.6 points (sd 1.12; 7 to 18). The mean total Engh radiological score score was 21.54 (sd 5.77; 3.5 to 27), with 95.81% of 'confirmed ingrowth', according to Engh's classification. With aseptic loosening or pain as endpoints, three AGB II stems (0.26%) failed, giving a 99.7% survival rate (se 0.002; 95% confidence interval (CI) 0.994 to 1) at 14 years' follow-up. The survival of patients ≤ 50 years of age (99.0% (se 0.011; 95% CI 0.969 to 1)) did not differ significantly from those of patients aged > 50 years (99.8% (se 0.002; 95% CI 0.994 to 1)). This study confirmed the excellent long-term results currently achieved with the ABG II proximally HA-coated monobloc stem. Cite this article: Bone Joint J 2013;95-B:1610-16.

Entities:  

Keywords:  Clinical follow-up; HA; Hip arthroplasty; Hydroxyapatite; Proximally-coated stem; Radiological patterns; Survival

Mesh:

Substances:

Year:  2013        PMID: 24293589     DOI: 10.1302/0301-620X.95B12.31167

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  6 in total

1.  Varus stem positioning does not affect long-term functional outcome in cementless anatomical total hip arthroplasty.

Authors:  Remy Coulomb; Alexandre Laborde; Vincent Haignère; François Bauzou; Philippe Marchand; Pascal Kouyoumdjian
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-06       Impact factor: 3.067

2.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

3.  Radiographic evaluation of early periprosthetic acetabular bone contrast and prosthetic head acetabular coverage after uncemented and cemented total hip prosthesis in dogs.

Authors:  Ayman A Mostafa; Karin Lucas; Ingo Nolte; Patrick Wefstaedt
Journal:  BMC Vet Res       Date:  2016-12-03       Impact factor: 2.741

4.  Effects of Nano-Hydroxyapatite/Polyetheretherketone-Coated, Sandblasted, Large-Grit, and Acid-Etched Implants on Inflammatory Cytokines and Osseointegration in a Peri-Implantitis Model in Beagle Dogs.

Authors:  Hua-Wei Yang; Xiao-Shan Tang; Zhuo-Wei Tian; Yang Wang; Wen-Yi Yang; Jing-Zhou Hu
Journal:  Med Sci Monit       Date:  2017-09-25

5.  Good stability of a cementless, anatomically designed femoral stem in aging women: a 9-year RSA study of 32 patients.

Authors:  Erik Aro; Jessica J Alm; Niko Moritz; Kimmo Mattila; Hannu T Aro
Journal:  Acta Orthop       Date:  2018-07-10       Impact factor: 3.717

Review 6.  Periprosthetic fracture as a late mode of failure of the Anatomique Benoist Girard II femoral prosthesis.

Authors:  Jonathan S Mulford; Ronnie Mathew; David Penn; Alana R Cuthbert; Richard De Steiger
Journal:  ANZ J Surg       Date:  2022-02-21       Impact factor: 2.025

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.