Literature DB >> 24291268

Fluorescent sensor for selective determination of copper ion based on N-acetyl-L-cysteine capped CdHgSe quantum dots.

Qingqing Wang1, Xiangyang Yu1, Guoqing Zhan1, Chunya Li2.   

Abstract

Using N-acetyl-L-cysteine as a stabilizer, well water-dispersed, high-quality and stable CdHgSe quantum dots were facilely synthesized via a simple aqueous phase method. The as-prepared N-acetyl-L-cysteine capped CdHgSe quantum dots were thoroughly characterized by transmission electron microscopy, X-ray diffraction spectroscopy and FTIR. A fluorescent sensor for selective determination of copper ions was developed using N-acetyl-L-cysteine capped CdHgSe quantum dots as fluorescent probe. The fluorescence intensity of N-acetyl-L-cysteine capped CdHgSe quantum dots decreased when interacted with copper ions due to the formation of coordination complex and aggregates. The method possesses high selectivity and is not influenced by some potential interferences such as Ag(+), Zn(2+), Co(2+) and Ni(2+). Under the optimal conditions, the change of fluorescence intensity (ΔI) was linearly proportional to the concentration of copper ions in the range of 1.0×10(-9)-4.0×10(-7) mol L(-1), with a detection limit as low as 2.0×10(-10) mol L(-1) (S/N=3). The developed method had been successfully employed to determine Cu(2+) in shrimp and South-lake water samples, and the results were verified by atomic absorption spectroscopy. The fluorescent sensor was demonstrated to be selective, sensitive and simple for copper ion determination, and promise for practical applications.
© 2013 Published by Elsevier B.V.

Entities:  

Keywords:  CdHgSe; Copper ion; N-acetyl-l-cysteine; Quantum dots; Sensor

Mesh:

Substances:

Year:  2013        PMID: 24291268     DOI: 10.1016/j.bios.2013.11.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Fluorescence Determination of Warfarin Using TGA-capped CdTe Quantum Dots in Human Plasma Samples.

Authors:  A Dehbozorgi; J Tashkhourian; S Zare
Journal:  J Fluoresc       Date:  2015-10-19       Impact factor: 2.217

2.  Room-Temperature Phosphorescence Turn-on Detection of DNA Based on Riboflavin-Modulated Manganese Doped Zinc Sulfide Quantum Dots.

Authors:  Yan Gong; Zhefeng Fan
Journal:  J Fluoresc       Date:  2015-12-14       Impact factor: 2.217

Review 3.  Fluorescent Sensors for the Detection of Heavy Metal Ions in Aqueous Media.

Authors:  Nerea De Acha; César Elosúa; Jesús M Corres; Francisco J Arregui
Journal:  Sensors (Basel)       Date:  2019-01-31       Impact factor: 3.576

  3 in total