Two-leg alternate loading model--a different approach to biomechanical investigations of fixation methods of the injured pelvic ring with focus on the pubic symphysis.

Yash Agarwal1, Stefan Doebele2, Markus Windolf3, Thomas Shiozawa4, Boyko Gueorguiev5, Fabian M Stuby6.   

Abstract

The dorsal component of the pelvic ring is considered to be the most essential element for the stability of the pelvic ring. None of the current biomechanical set-ups include the effect of shear stresses by alternating loads that the pelvic ring has to withstand during walking. We hypothesize that a biomechanical test set-up with two-leg alternate loading will lead to stress imitation at the pubic symphysis that are more similar to existing strains than other test set-ups, and would, therefore, be more adequate for biomechanical testing of fixation methods. A new biomechanical two-leg standing test set-up with an alternate pelvic loading was constructed and was validated with six human pelvises from fresh frozen cadavers. Three-dimensional motion tracking was performed. The specimens were subjected to a non-destructive quasi-static test and a non-destructive cyclic test with progressive load amplitude from 170 N to 340 N over 1000 cycles. The initial rotational 'range of motion' and 'mean displacement' around the vertical axis for a pre-load of 170 N was about 0.3° and 0.2°, respectively, increasing by 0.1-0.2° at a load of 340 N. The rotation around the vertical axis and the translation along the frontal horizontal axis confirmed the stability of the pubic symphysis. The rate of ascend of displacements decreased, once the rotation reached 1° or the translation reached 1mm. The current biomechanical test set-up was compared with previous clinical findings, and the method was found valid for measuring inter-segmentary movements at the pubic symphysis.
© 2013 Published by Elsevier Ltd.

Entities:  

Keywords:  Biomechanics; Human movement; Pelvic bone; Pubic symphysis

Mesh:

Year:  2013        PMID: 24290178     DOI: 10.1016/j.jbiomech.2013.11.008

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Postoperative stability following a triple pelvic osteotomy is affected by implant configuration: a finite element analysis.

Authors:  Henrik Hedelin; Erik Brynskog; Per Larnert; Johan Iraeus; Tero Laine; Kerstin Lagerstrand
Journal:  J Orthop Surg Res       Date:  2022-05-15       Impact factor: 2.677

2.  Symphyseal fixation in open book injuries cannot fully compensate anterior SI joint injury-A biomechanical study in a two-leg alternating load model.

Authors:  Fabian M Stuby; Mark Lenz; Stefan Doebele; Yash Agarwal; Hristo Skulev; Björn G Ochs; Jörn Zwingmann; Boyko Gueorguiev
Journal:  PLoS One       Date:  2017-11-27       Impact factor: 3.240

3.  Comparison of Biomechanical Performance of Five Different Treatment Approaches for Fixing Posterior Pelvic Ring Injury.

Authors:  Yongtao Lu; Yiqian He; Weiteng Li; Zhuoyue Yang; Ruifei Peng; Li Yu
Journal:  J Healthc Eng       Date:  2020-01-22       Impact factor: 2.682

4.  Safety and effectiveness of minimally invasive sacroiliac joint fusion in women with persistent post-partum posterior pelvic girdle pain: 12-month outcomes from a prospective, multi-center trial.

Authors:  Robyn Capobianco; Daniel Cher
Journal:  Springerplus       Date:  2015-10-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.