Literature DB >> 24289911

Fluorescence-enhanced robotic radical prostatectomy using real-time lymphangiography and tissue marking with percutaneous injection of unconjugated indocyanine green: the initial clinical experience in 50 patients.

Ted B Manny1, Manish Patel1, Ashok K Hemal2.   

Abstract

BACKGROUND: Pilot studies have demonstrated the utility of indocyanine green (ICG) sentinel lymphadenectomy for prostate cancer. Prior work has used ICG with radiocontrast agents injected at a separate procedure and relied on assistant-controlled fluorescence systems, making the technique costly and cumbersome.
OBJECTIVE: To describe the initial optimization and feasibility of fluorescence-enhanced robotic radical prostatectomy (FERRP) using real-time injection of ICG for tissue marking and identification of sentinel lymphatic drainage visualized by a fully integrated surgeon-controlled system. DESIGN, SETTING, AND PARTICIPANTS: Patients with clinically localized prostate cancer at a tertiary referral center were offered FERRP. Ten patients participated in a pilot arm in which ICG dosing and injection technique were optimized. Fifty consecutive patients then underwent FERRP. SURGICAL PROCEDURE: After development of the space of Retzius, 0.4 ml of a 2.5 mg/ml ICG solution were injected into each lobe of the prostate using a robotically guided percutaneous needle. After ICG was allowed to travel through the pelvic lymphatics, lymphadenectomy was performed from the endopelvic fascia to the aortic bifurcation. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Parameters describing the time course of tissue fluorescence and pelvic lymphangiography were systematically recorded. Lymphatic packets containing fluorescent nodes were considered sentinel. RESULTS AND LIMITATIONS: Percutaneous, robotic-guided ICG injection proved superior to cystoscope or transrectal delivery. Tissue marking was achieved in all patients, positively identifying the prostate with uniform fluorescence relative to the obturator nerve, seminal vesicles, vas deferens, and neurovascular pedicles at a mean time of 10 min postinjection. Sentinel nodes were identified in 76% of patients at a mean time of 30 min postinjection and had 100% sensitivity, 75.4% specificity, 14.6% positive predictive value, and 100% negative predictive value for the detection of nodal metastasis.
CONCLUSIONS: FERRP is safe, feasible, and allows for reliable prostate tissue marking and identification of sentinel lymphatic drainage in the majority of patients. ICG sentinel nodes are highly sensitive but relatively nonspecific for the detection of nodal metastasis.
Copyright © 2013. Published by Elsevier B.V.

Entities:  

Keywords:  Indocyanine green; Lymphangiography; Prostatectomy; Robotics

Mesh:

Substances:

Year:  2013        PMID: 24289911     DOI: 10.1016/j.eururo.2013.11.017

Source DB:  PubMed          Journal:  Eur Urol        ISSN: 0302-2838            Impact factor:   20.096


  32 in total

Review 1.  Novel Technologies in Urologic Surgery: a Rapidly Changing Scenario.

Authors:  Giorgio Gandaglia; Peter Schatteman; Geert De Naeyer; Frederiek D'Hondt; Alexandre Mottrie
Journal:  Curr Urol Rep       Date:  2016-03       Impact factor: 3.092

Review 2.  Advances in fluorescent-image guided surgery.

Authors:  Mark J Landau; Daniel J Gould; Ketan M Patel
Journal:  Ann Transl Med       Date:  2016-10

Review 3.  Sentinel node evaluation in prostate cancer.

Authors:  Ramkishen Narayanan; Timothy G Wilson
Journal:  Clin Exp Metastasis       Date:  2018-09-05       Impact factor: 5.150

Review 4.  Sentinel lymph node biopsy in renal malignancy: The past, present and future.

Authors:  Tharani Mahesan; Alberto Coscione; Ben Ayres; Nick Watkin
Journal:  World J Nephrol       Date:  2016-03-06

Review 5.  Molecular Targeted Fluorescence-Guided Intraoperative Imaging of Bladder Cancer Nodal Drainage Using Indocyanine Green During Radical and Partial Cystectomy.

Authors:  Manish N Patel; Ashok K Hemal
Journal:  Curr Urol Rep       Date:  2016-10       Impact factor: 3.092

Review 6.  A review of performance of near-infrared fluorescence imaging devices used in clinical studies.

Authors:  B Zhu; E M Sevick-Muraca
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

7.  Anatomical localization of radiocolloid tracer deposition affects outcome of sentinel node procedures in prostate cancer.

Authors:  C M de Korne; E M Wit; J de Jong; R A Valdés Olmos; T Buckle; F W B van Leeuwen; H G van der Poel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-08-03       Impact factor: 9.236

8.  Fluorescence-supported lymphography and extended pelvic lymph node dissection in robot-assisted radical prostatectomy: a prospective, randomized trial.

Authors:  Nina Natascha Harke; Michael Godes; Christian Wagner; Mustapha Addali; Bernhard Fangmeyer; Katarina Urbanova; Boris Hadaschik; Jorn H Witt
Journal:  World J Urol       Date:  2018-05-16       Impact factor: 4.226

9.  Hyaluronic acid formulation of near infrared fluorophores optimizes surgical imaging in a prostate tumor xenograft.

Authors:  Joshua J Souchek; Nicholas E Wojtynek; William M Payne; Megan B Holmes; Samikshan Dutta; Bowen Qi; Kaustubh Datta; Chad A LaGrange; Aaron M Mohs
Journal:  Acta Biomater       Date:  2018-06-08       Impact factor: 8.947

10.  Evaluation to Differentiate between Tumor Lesions and the Parenchyma in Partial Nephrectomies for Renal Tumors Based on Quantitative Fluorescence Imaging Using Indocyanine Green Dye.

Authors:  Norihito Soga; Akihito Inoko; Jun Furusawa; Yuji Ogura
Journal:  Curr Urol       Date:  2019-10-01
View more