Literature DB >> 24289900

Bolt axial stress measurement based on a mode-converted ultrasound method using an electromagnetic acoustic transducer.

Xu Ding1, Xinjun Wu2, Yugang Wang3.   

Abstract

A method is proposed to measure the stress on a tightened bolt using an electromagnetic acoustic transducer (EMAT). A shear wave is generated by the EMAT, and a longitudinal wave is obtained from the reflection of the shear wave due to the mode conversion. The ray paths of the longitudinal and the shear wave are analyzed, and the relationship between the bolt axial stress and the ratio of time of flight between two mode waves is then formulated. Based on the above outcomes, an EMAT is developed to measure the bolt axial stress without loosening the bolt, which is required in the conventional EMAT test method. The experimental results from the measurement of the bolt tension show that the shear and the mode-converted longitudinal waves can be received successfully, and the ratio of the times of flight of the shear and the mode-converted longitudinal waves is linearly proportional to the bolt axial tension. The non-contact characteristic of EMAT eliminates the effect of the couplant and also makes the measurement more convenient than the measurement performed using the piezoelectric transducer. This method provides a promising way to measure the stress on tightened bolts.
Copyright © 2013 Elsevier B.V. All rights reserved.

Keywords:  Acoustoelasticity; Bolt axial stress; Electromagnetic acoustic transducer; Mode conversion; Time of flight

Mesh:

Year:  2013        PMID: 24289900     DOI: 10.1016/j.ultras.2013.11.003

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  3 in total

1.  A New Axial Stress Measurement Method for High-Strength Short Bolts Based on Stress-Dependent Scattering Effect and Energy Attenuation Coefficient.

Authors:  Tong Fu; Ping Chen; Aijun Yin
Journal:  Sensors (Basel)       Date:  2022-06-22       Impact factor: 3.847

2.  A New Design of the Dual-Mode and Pure Longitudinal EMAT by Using a Radial-Flux-Focusing Magnet.

Authors:  Xu Zhang; Weiwen Li; Bo Li; Jun Tu; Chunhui Liao; Qiao Wu; Sheng Feng; Xiaochun Song
Journal:  Sensors (Basel)       Date:  2022-02-09       Impact factor: 3.576

3.  A Longitudinal Mode Electromagnetic Acoustic Transducer (EMAT) Based on a Permanent Magnet Chain for Pipe Inspection.

Authors:  Ming Cong; Xinjun Wu; Chunqiao Qian
Journal:  Sensors (Basel)       Date:  2016-05-21       Impact factor: 3.576

  3 in total