Literature DB >> 24287430

Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system.

Sachi Kuranuki1, Toshiyuki Sato, Seiki Okada, Samiko Hosoya, Akinobu Seko, Kaya Sugihara, Teiji Nakamura.   

Abstract

OBJECTIVE: To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake.
METHODS: Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the areas, and calculating IG-AUC based on glucose levels in the hydrogels. Glycemic index (GI) was determined using IG-AUC and reference AUC measured by blood sampling.
RESULTS: IG-AUC strongly correlated with reference AUC (R = 0.91), and GI determined using IG-AUC showed good correlation with that determined by reference AUC (R = 0.88).
CONCLUSIONS: IG-AUC obtained by MIET can accurately predict the postprandial glucose excursion without blood sampling. In addition, feasibility of GI measurement by MIET was confirmed.

Entities:  

Keywords:  glucose monitor; glycemic index; interstitial fluid; nutrition education; postprandial hyperglycemia

Mesh:

Substances:

Year:  2013        PMID: 24287430     DOI: 10.1260/2040-2295.4.4.529

Source DB:  PubMed          Journal:  J Healthc Eng        ISSN: 2040-2295            Impact factor:   2.682


  3 in total

1.  Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring.

Authors:  Satoshi Ugi; Hiroshi Maegawa; Katsutaro Morino; Yoshihiko Nishio; Toshiyuki Sato; Seiki Okada; Yasuo Kikkawa; Toshihiro Watanabe; Hiromu Nakajima; Atsunori Kashiwagi
Journal:  Diabetes Metab J       Date:  2016-07-26       Impact factor: 5.376

2.  Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients.

Authors:  Mei Uemura; Yutaka Yano; Toshinari Suzuki; Taro Yasuma; Toshiyuki Sato; Aya Morimoto; Samiko Hosoya; Chihiro Suminaka; Hiromu Nakajima; Esteban C Gabazza; Yoshiyuki Takei
Journal:  Diabetes Metab J       Date:  2017-08       Impact factor: 5.376

Review 3.  Sensors for Fetal Hypoxia and Metabolic Acidosis: A Review.

Authors:  Gerard Cummins; Jessica Kremer; Anne Bernassau; Andrew Brown; Helen L Bridle; Holger Schulze; Till T Bachmann; Michael Crichton; Fiona C Denison; Marc P Y Desmulliez
Journal:  Sensors (Basel)       Date:  2018-08-13       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.