| Literature DB >> 24282388 |
Wang Hui-Li1, Tan Yan-Bin, Qin Si-Feng, Zhang Zhe.
Abstract
Geometric nonlinearity of self-anchored cable-stayed suspension bridges is studied in this paper. The repercussion of shrinkage and creep of concrete, rise-to-span ratio, and girder camber on the system is discussed. A self-anchored cable-stayed suspension bridge with a main span of 800 m is analyzed with linear theory, second-order theory, and nonlinear theory, respectively. In the condition of various rise-to-span ratios and girder cambers, the moments and displacements of both the girder and the pylon under live load are acquired. Based on the results it is derived that the second-order theory can be adopted to analyze a self-anchored cable-stayed suspension bridge with a main span of 800 m, and the error is less than 6%. The shrinkage and creep of concrete impose a conspicuous impact on the structure. And it outmatches suspension bridges for system stiffness. As the rise-to-span ratio increases, the axial forces of the main cable and the girder decline. The system stiffness rises with the girder camber being employed.Entities:
Mesh:
Year: 2013 PMID: 24282388 PMCID: PMC3825120 DOI: 10.1155/2013/734387
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
Figure 1Arrangement diagram of Dalian Gulf Bridge/m.
Figure 2Envelope of main girder moment.
Figure 3Envelope of main girder displacement.
Figure 4Envelope of pylon moment.
Figure 5Envelope of pylon displacement (positive direction pointing to mid-span).
Nonlinear effect of live load.
| Nonlinearity | Second-order | Relatively deviation% | Linear | Relatively deviation% | ||
|---|---|---|---|---|---|---|
| Moment at midspan of girder/(103 KN·m) | Max | 101.24 | 101.19 | −0.05 | 101.7 | 0.45 |
| Min | −15.00 | −14.96 | −0.27 | −15.04 | 0.27 | |
| Moment at root of pylon/(103 KN·m) | Max | 285.61 | 283.20 | −0.84 | 162.80 | −47.79 |
| Min | −184.12 | −185.48 | 0.74 | −96.65 | −47.51 | |
| Displacement at midspan of girder/(mm) | Max | 13.3 | 13.4 | 0.75 | 21.2 | 59.40 |
| Min | −1180 | −1186 | 0.51 | −1189 | 0.76 | |
| Displacement at end of girder/(mm) | Max | 23.4 | 22.0 | −5.98 | 21.5 | −8.12 |
| Min | −0.84 | −0.86 | 2.38 | −0.36 | −57.14 | |
| Displacement at top of pylon/(mm) | Max | 118.0 | 115.0 | −2.54 | 120.0 | 1.69 |
| Min | −6.6 | −6.6 | 0.00 | −9.1 | 37.88 |
Effect of shrinkage and creep of concrete.
| Position | Moment/(KN·m) | Displacement/(mm) |
|---|---|---|
| Girder | ||
| Midspan | −358 | −36.6 |
| Supporting point at pylon | −11700 | −1.0 |
| Pylon | 36150 | 27.2 |
The moment of pylon takes place at the root. The displacement of pylon takes place at top and the positive direction points to midspan. The positive direction of girder displacement points to upward side.
Figure 6Effects of rise-span of main cable.
Effect of camber of main girder.
| 0 camber | 2.9 m camber | Relatively deviation% | |
|---|---|---|---|
| Midspan moment/(103 KN·m) | 101.19 | 99.18 | −1.99 |
| Midspan deflection/mm | 1186 | 1151 | −2.95 |