Literature DB >> 24282079

A membrane model from implicit elasticity theory: application to visceral pleura.

A D Freed1, J Liao, D R Einstein.   

Abstract

A Fungean solid is derived for membranous materials as a body defined by isotropic response functions whose mathematical structure is that of a Hookean solid where the elastic constants are replaced by functions of state derived from an implicit, thermodynamic, internal energy function. The theory utilizes Biot's (Lond Edinb Dublin Philos Mag J Sci 27:468-489, 1939) definitions for stress and strain that, in one-dimension, are the stress/strain measures adopted by Fung (Am J Physiol 28:1532-1544, 1967) when he postulated what is now known as Fung's law. Our Fungean membrane model is parameterized against a biaxial data set acquired from a porcine pleural membrane subjected to three, sequential, proportional, planar extensions. These data support an isotropic/deviatoric split in the stress and strain-rate hypothesized by our theory. These data also demonstrate that the material response is highly nonlinear but, otherwise, mechanically isotropic. These data are described reasonably well by our otherwise simple, four-parameter, material model.

Entities:  

Mesh:

Year:  2013        PMID: 24282079      PMCID: PMC4035472          DOI: 10.1007/s10237-013-0542-8

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  8 in total

1.  Review: Computer Methods in Membrane Biomechanics.

Authors:  J. D. Humphrey
Journal:  Comput Methods Biomech Biomed Engin       Date:  1998       Impact factor: 1.763

2.  Elastic properties of single elastic fibers.

Authors:  R W CARTON; J DAINAUSKAS; J W CLARK
Journal:  J Appl Physiol       Date:  1962-05       Impact factor: 3.531

3.  Biaixal stress-stretch behavior of the mitral valve anterior leaflet at physiologic strain rates.

Authors:  Jonathan S Grashow; Ajit P Yoganathan; Michael S Sacks
Journal:  Ann Biomed Eng       Date:  2006-02-01       Impact factor: 3.934

4.  A mechanism for the decrease in stiffness of bioprosthetic heart valve tissues after cross-linking.

Authors:  I Vesely
Journal:  ASAIO J       Date:  1996 Nov-Dec       Impact factor: 2.872

5.  Pseudoelasticity of excised visceral pleura.

Authors:  J D Humphrey; D L Vawter; R P Vito
Journal:  J Biomech Eng       Date:  1987-05       Impact factor: 2.097

6.  An Implicit Elastic Theory for Lung Parenchyma.

Authors:  Alan D Freed; Daniel R Einstein
Journal:  Int J Eng Sci       Date:  2013-01       Impact factor: 8.843

7.  Elasticity of soft tissues in simple elongation.

Authors:  Y C Fung
Journal:  Am J Physiol       Date:  1967-12

8.  Effects of decellularization on the mechanical and structural properties of the porcine aortic valve leaflet.

Authors:  Jun Liao; Erinn M Joyce; Michael S Sacks
Journal:  Biomaterials       Date:  2008-03       Impact factor: 12.479

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.