Literature DB >> 24281746

Application of internal electrodes to the oesophageal and tracheal tube in an animal trial: evaluation of its clinical and technical potentiality in electrical impedance tomography.

Michael Czaplik1, Christoph Hoog Antink, Rolf Rossaint, Steffen Leonhardt.   

Abstract

Electrical impedance tomography (EIT) is of potential medical interest e.g., to optimize ventilator settings during mechanical ventilation. Nevertheless there are still several challenges. Although electrode belts are commonly used and promoted, they are not necessarily adequate for the long-term monitoring of patients in intensive-care units (ICU). ICU patients are usually equipped with breathing tubes and feeding tubes, ideal surfaces to attach EIT electrodes to. The aim of our study was therefore to examine the potentiality of internal electrodes in a porcine animal trial. Following an animal trial protocol studying acute lung injury, additional EIT measurements were obtained both with conventional electrodes set upon a rubber belt and after having moved the electrodes internally in seven pigs. For this reason the two most dorsally located electrodes were selected. An adjacent stimulation and measurement pattern was used, and resulting voltages in the time and frequency domains as well as within reconstructed images were examined to compare perfusion and ventilation data qualitatively and quantitatively. Particularly, lung morphology as well as signal strength for both the mediastinal and lung region were studied. All animals were submitted to the additional protocol without any adverse events. Distinguishability of lungs was improved in reconstructed frames. The resulting sensitivity of measured electrical impedance was enhanced around the mediastinal region and even cardiac-related activity was significantly increased by a factor of up to 6. In conclusion the application of internal electrodes appears to be beneficial for diverse clinical purposes and should be addressed in further studies.

Entities:  

Mesh:

Year:  2013        PMID: 24281746     DOI: 10.1007/s10877-013-9536-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Level-set-based reconstruction algorithm for EIT lung images: first clinical results.

Authors:  Peyman Rahmati; Manuchehr Soleimani; Sven Pulletz; Inéz Frerichs; Andy Adler
Journal:  Physiol Meas       Date:  2012-04-24       Impact factor: 2.833

Review 2.  Impedance tomography as a new monitoring technique.

Authors:  Thomas Muders; Henning Luepschen; Christian Putensen
Journal:  Curr Opin Crit Care       Date:  2010-06       Impact factor: 3.687

3.  Uses and abuses of EIDORS: an extensible software base for EIT.

Authors:  Andy Adler; William R B Lionheart
Journal:  Physiol Meas       Date:  2006-04-18       Impact factor: 2.833

4.  Study of the optimum level of electrode placement for the evaluation of absolute lung resistivity with the Mk3.5 EIT system.

Authors:  S Nebuya; M Noshiro; A Yonemoto; S Tateno; B H Brown; R H Smallwood; P Milnes
Journal:  Physiol Meas       Date:  2006-04-20       Impact factor: 2.833

5.  Evaluation of different stimulation and measurement patterns based on internal electrode: application in cardiac impedance tomography.

Authors:  J Nasehi Tehrani; T I Oh; C Jin; A Thiagalingam; A McEwan
Journal:  Comput Biol Med       Date:  2012-09-25       Impact factor: 4.589

6.  A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2.

Authors:  Tong In Oh; Hun Wi; Do Yub Kim; Pil Joong Yoo; Eung Je Woo
Journal:  Physiol Meas       Date:  2011-06-07       Impact factor: 2.833

Review 7.  Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

Authors:  Steffen Leonhardt; Burkhard Lachmann
Journal:  Intensive Care Med       Date:  2012-09-20       Impact factor: 17.440

8.  In vivo electrical bioimpedance characterization of human lung tissue during the bronchoscopy procedure. A feasibility study.

Authors:  Benjamin Sanchez; Gerd Vandersteen; Irene Martin; Diego Castillo; Alfons Torrego; Pere J Riu; Johan Schoukens; Ramon Bragos
Journal:  Med Eng Phys       Date:  2012-10-09       Impact factor: 2.242

9.  Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients.

Authors:  Ido G Bikker; Steffen Leonhardt; Dinis Reis Miranda; Jan Bakker; Diederik Gommers
Journal:  Crit Care       Date:  2010-05-30       Impact factor: 9.097

10.  Modelling of an oesophageal electrode for cardiac function tomography.

Authors:  J Nasehi Tehrani; C Jin; A L McEwan
Journal:  Comput Math Methods Med       Date:  2012-03-15       Impact factor: 2.238

View more
  2 in total

Review 1.  Journal of clinical monitoring and computing 2014 end of year summary: respiration.

Authors:  D S Karbing; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2015-03-04       Impact factor: 2.502

2.  The global inhomogeneity index assessed by electrical impedance tomography overestimates PEEP requirement in patients with ARDS: an observational study.

Authors:  Serge J H Heines; Sebastiaan A M de Jongh; Ulrich Strauch; Iwan C C van der Horst; Marcel C G van de Poll; Dennis C J J Bergmans
Journal:  BMC Anesthesiol       Date:  2022-08-15       Impact factor: 2.376

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.