Evaluation of alginate as a substitute for root-surrounding tissues in electronic root canal measurements.

Mariusz Lipski1, Marlena Trąbska-Świstelnicka, Krzysztof Woźniak, Elżbieta Dembowska, Agnieszka Droździk.   

Abstract

Alginate as a substitute for root-surrounding tissue was investigated. The electronic working lengths of root canals under clinical conditions were compared with an in vitro simulation of the same teeth extracted and embedded in alginate. The working lengths in 26 teeth were determined on two occasions using an electronic apex locator, before extraction and after extraction with the same teeth embedded in an alginate mass. The apical 4 mm of the root canals were exposed following the measurements, and the distances between the apical constrictions and the tips of files repositioned in the canals were measured and recorded. The mean distance between the file tip and the constriction was +0.33 mm (±0.38) in vivo and +0.32 mm (±0.30) in vitro. The Wilcoxon signed-rank test indicated that these means were not significantly different. The apical constriction was assessed to be within the limits of 0.5 mm in 80.7% of in vivo cases and in 76.9% of extracted teeth. Statistical analysis demonstrated that there was no significant difference between the results recorded in vivo and in vitro regarding apical constriction localisation. Based on the results of this study, the alginate mass is a useful tool in evaluating the performance of electronic apex locators.
© 2012 The Authors. Australian Endodontic Journal © 2012 Australian Society of Endodontology.

Entities:  

Keywords:  alginate mass; apex locator; model; root canal measurement

Mesh:

Substances:

Year:  2012        PMID: 24279664     DOI: 10.1111/j.1747-4477.2012.00367.x

Source DB:  PubMed          Journal:  Aust Endod J        ISSN: 1329-1947            Impact factor:   1.659


  4 in total

1.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

2.  The accuracy of the auto-stop function of different endodontic devices in detecting the apical constriction.

Authors:  David W Christofzik; Andreas Bartols; Mahmoud Khaled; Birte Größner-Schreiber; Christof E Dörfer
Journal:  BMC Oral Health       Date:  2017-11-29       Impact factor: 2.757

3.  Comparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: An in vitro study.

Authors:  Vidya Saraswathi; Archit Kedia; Tina Puthen Purayil; Vasudev Ballal; Aakriti Saini
Journal:  J Conserv Dent       Date:  2016 Sep-Oct

4.  Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An In Vitro Study.

Authors:  Masoud Saatchi; Shiva Iravani; Mehrdad Akhavan Khaleghi; Amin Mortaheb
Journal:  Iran Endod J       Date:  2017
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.