Literature DB >> 24278924

Placement of implants with platform-switched Morse taper connections with the implant-abutment interface at different levels in relation to the alveolar crest: a short-term (1-year) randomized prospective controlled clinical trial.

Theofilos Koutouzis, Rodrigo Neiva, Jörg Nonhoff, Tord Lundgren.   

Abstract

PURPOSE: This study sought to prospectively evaluate changes in marginal bone levels and soft tissue dimensions around platform-switched, Morse taper-connection implants placed with the implant-abutment interface (IAI) at different positions in relation to the alveolar crest.
MATERIALS AND METHODS: Thirty patients in need of single-tooth rehabilitations were randomly assigned to three groups based on the position of the IAI in relation to the alveolar crest at the time of implant placement. Implants in groups 0, 1, and 2 (n = 10 in each group) were placed at the bone level or 1 mm and 2 mm below the buccal aspect of the alveolar crest, respectively. Four months later, the implants were restored with crowns. Clinical parameters were recorded at 4 and 12 months, and marginal bone levels were assessed radiographically at placement, 4 months, and 12 months.
RESULTS: Mean marginal bone loss below the implant platform in group 0 implants was 0.18 ± 0.27 mm at 4 months and 0.27 ± 0.45 mm at 12 months. All implants in groups 1 and 2 exhibited no marginal bone loss below the implant platform, since the first bone-to-implant contact was located at or above the implant margin. At 12 months, implants in groups 1 and 2 exhibited greater mean bone loss above the implant platform compared to implants in group 0, but the differences were not statistically significant (group 0, 0.64 ± 0.49 mm; group 1, 0.81 ± 0.31 mm; group 2, 1.20 ± 0.68 mm). Implants in groups 1 and 2 exhibited a statistically significantly higher percentage of implant surfaces with bone on the implant platform compared to group 0 implants (90% versus 35%).
CONCLUSIONS: In the present study, differences in peri-implant bone responses existed for implants placed with the IAI at different locations in relation to the alveolar crest.

Entities:  

Mesh:

Year:  2013        PMID: 24278924     DOI: 10.11607/jomi.3184

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  2 in total

Review 1.  Influence of subcrestal implant placement compared with equicrestal position on the peri-implant hard and soft tissues around platform-switched implants: a systematic review and meta-analysis.

Authors:  Cristina Valles; Xavier Rodríguez-Ciurana; Marco Clementini; Mariana Baglivo; Blanca Paniagua; Jose Nart
Journal:  Clin Oral Investig       Date:  2018-01-08       Impact factor: 3.573

2.  Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?

Authors:  B Alper Gultekin; Ali Sirali; Pinar Gultekin; Serdar Yalcin; Eitan Mijiritsky
Journal:  Biomed Res Int       Date:  2016-08-31       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.