Literature DB >> 2427751

A comparison of isobutyl 2-cyanoacrylate glue, fibrin adhesive, and oxidized regenerated cellulose for control of needle hole bleeding from polytetrafluoroethylene vascular prostheses.

R J Barbalinardo, P Citrin, C D Franco, R W Hobson.   

Abstract

Prolonged anastomotic and needle hole bleeding from synthetic vascular prostheses is a common surgical problem in heparinized patients and in the patient with a coagulopathy. The relative effectiveness of various hemostatic agents has not previously been determined by controlled comparisons. In this study 6 mm polytetrafluoroethylene (PTFE) vascular prostheses were used to perform carotid-carotid and femorofemoral bypasses in eight heparinized dogs. The relative effectiveness of isobutyl 2-cyanoacrylate, fibrin adhesive, and oxidized regenerated cellulose was determined by application of these hemostatic agents to three sources of bleeding: arterial-PTFE anastomoses, PTFE-PTFE anastomoses, and 18-gauge needle holes in PTFE vascular prostheses. The mean time to hemostasis (MTH) was determined for each hemostatic agent. Although application of isobutyl 2-cyanoacrylate resulted in the shortest MTH in each experimental group, the reported inflammatory response that it induces and its possible carcinogenicity limits its availability for clinical use. Application of fibrin adhesive prepared from single-donor hepatitis-screened plasma resulted in a significantly shorter MTH in each experimental group when compared with oxidized regenerated cellulose. We recommend clinical use of fibrin adhesive to control needle hole and anastomotic bleeding from PTFE vascular prostheses.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2427751

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  3 in total

1.  New application method of fibrin glue for more effective hemostasis in cardiovascular surgery: rub-and-spray method.

Authors:  Naoki Minato; Tomoki Shimokawa; Yuji Katayama; Noriko Yamada; Masayuki Sakaguchi; Manabu Itoh
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2004-08

2.  Comparison of Arterial Repair through the Suture, Suture with Fibrin or Cyanoacrylate Adhesive in Ex-Vivo Porcine Aortic Segment.

Authors:  Marcus Vinicius H de Carvalho; Evaldo Marchi; Edmir Américo Lourenço
Journal:  Braz J Cardiovasc Surg       Date:  2017 Nov-Dec

3.  Randomized trial comparing Quixil surgical sealant with Kaltostat hemostatic dressing to control suture line bleeding after carotid endarterectomy with ePTFE patch reconstruction.

Authors:  Martin P Sintler; Asif Mahmood; Simon R G Smith; Malcolm H Simms; Rajiv K Vohra
Journal:  World J Surg       Date:  2005-10       Impact factor: 3.282

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.