Literature DB >> 24273249

Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement.

Stefan Stortecky1, Dik Heg, Steffen Gloekler, Peter Wenaweser, Stephan Windecker, Lutz Buellesfeld.   

Abstract

AIMS: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). METHODS AND
RESULTS: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm).
CONCLUSIONS: MSCT-based 3D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.

Entities:  

Mesh:

Year:  2014        PMID: 24273249     DOI: 10.4244/EIJV10I3A59

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  9 in total

Review 1.  CT support of cardiac structural interventions.

Authors:  Michaela M Hell; Stephan Achenbach
Journal:  Br J Radiol       Date:  2019-03-11       Impact factor: 3.039

2.  The Changing Paradigm in the Treatment of Structural Heart Disease and the Need for the Interventional Imaging Specialist.

Authors:  Nina C Wunderlich; Harald Küx; Felix Kreidel; Ralf Birkemeyer; Robert J Siegel
Journal:  Interv Cardiol       Date:  2016-10

Review 3.  Hybrid Imaging During Transcatheter Structural Heart Interventions.

Authors:  Patric Biaggi; Covadonga Fernandez-Golfín; Rebecca Hahn; Roberto Corti
Journal:  Curr Cardiovasc Imaging Rep       Date:  2015

Review 4.  3D transoesophageal echocardiography in the TAVI sizing arena: should we do it and how do we do it?

Authors:  Caroline Bleakley; Mehdi Eskandari; Mark Monaghan
Journal:  Echo Res Pract       Date:  2017-03

Review 5.  The Pivotal Role of Imaging in TAVR Procedures.

Authors:  Caroline Bleakley; Mark J Monaghan
Journal:  Curr Cardiol Rep       Date:  2018-02-12       Impact factor: 2.931

6.  A modified system for classifying the bilateral superior pulmonary veins using three-dimensional computed tomography bronchography and angiography images.

Authors:  Jun Wang; Haoran Lin; Chengyu Bian; Zhipeng Chen; Jingjing Huang; Yang Xia; Weibing Wu; Quan Zhu; Mei Yuan; Liang Chen
Journal:  J Thorac Dis       Date:  2021-10       Impact factor: 2.895

7.  Fully automated measurement of aortic root anatomy using Philips HeartNavigator computed tomography software: fast, accurate, or both?

Authors:  Viktor Kočka; Lucie Bártová; Naďa Valošková; Marek Laboš; Jiří Weichet; Marek Neuberg; And Petr Toušek
Journal:  Eur Heart J Suppl       Date:  2022-03-30       Impact factor: 1.803

8.  Multi-Slice Computed Tomography Analysis in Patients Undergoing Transcatheter Aortic Valve Replacement - Impact of Workflows on Measurement of Virtual Aortic Annulus and Valve Size.

Authors:  Kerstin Piayda; Katharina Hellhammer; Verena Veulemans; Shazia Afzal; Kathrin Klein; Nora Berisha; Pia Leuders; Ralf Erkens; Julian Kirchner; Houtan Heidari; Malte Kelm; Gerald Antoch; Tobias Zeus; Christine Quast
Journal:  Front Cardiovasc Med       Date:  2022-06-21

9.  Quantification of abdominal aortic calcification: Inherent measurement errors in current computed tomography imaging.

Authors:  Ruben V C Buijs; Eva L Leemans; Marcel Greuter; Ignace F J Tielliu; Clark J Zeebregts; Tineke P Willems
Journal:  PLoS One       Date:  2018-02-28       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.