Literature DB >> 24273201

Changes in fetal cardiac axis between 8 and 15 weeks' gestation.

A McBrien1, L Howley, Y Yamamoto, D Hutchinson, A Hirose, P Sekar, V Jain, T Motan, J Trines, W Savard, L K Hornberger.   

Abstract

OBJECTIVES: To document changes in the normal embryonic/fetal cardiac axis in the late first and early second trimesters of pregnancy.
METHODS: Images from 188 fetal echocardiograms performed prospectively between 8 and 15 weeks' gestation in 166 healthy pregnancies and in 10 pregnancies with severe fetal heart disease were reviewed. For each echocardiogram, three measurements of the cardiac axis were taken in the axial plane at the level of the four-chamber view. Differences in mean embryonic/fetal cardiac axis at different gestational ages in the healthy pregnancies were compared.
RESULTS: The mean ± SD embryonic/fetal cardiac axis was 25.5 ± 11.5° from 8 + 0 to 9 + 6 weeks (Group  1), 40.4 ± 9.2° from 10 + 0 to 11 + 6 weeks (Group  2), 49.2 ± 7.4° from 12 + 0 to 12 + 6 weeks (Group  3), 50.6 ± 5.7° from 13 + 0 to 13 + 6 weeks (Group 4) and 48.6 ± 7.3° from 14 + 0 to 14 + 6 weeks (Group 5). Groups 1 and 2 were significantly different from each other and all other groups (P < 0.05). The results for 22 cases with repeat measurements from 8 + 0 to 11 + 6 and 12 + 0 to 14 + 6 weeks confirmed that the embryonic/fetal cardiac axis increased significantly (P < 0.001). In the cases with severe congenital heart disease, the cardiac axis was > 90th centile in four cases and < 10th centile in two cases.
CONCLUSIONS: The embryonic cardiac axis is relatively midline at 8 weeks and levorotates in the late first trimester. By 12 weeks' gestation, the normal leftward fetal cardiac axis is established and remains stable until at least 14 + 6 weeks. Observation of an abnormal cardiac axis in some cases of severe congenital heart disease prior to 15 weeks' gestation may assist in prenatal detection.
Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  axis; cardiac development; fetal echocardiography; fetal heart; first trimester; reference values

Mesh:

Year:  2013        PMID: 24273201     DOI: 10.1002/uog.12478

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

Review 1.  2014 First-trimester ultrasound forum from the Korean Society of Ultrasound in Obstetrics and Gynecology.

Authors:  Soo-Young Oh; Joon Seok Hong; Hyun-Joo Seol; Han Sung Hwang; Hyun Soo Park; Kunwoo Kim; Hyun Sun Ko; Dong-Wook Kwak; Moon Young Kim; Mi Hye Park; Min Jeong Oh; Joong Shin Park; Sa Jin Kim
Journal:  Obstet Gynecol Sci       Date:  2015-01-16

Review 2.  First Trimester Ultrasound in Prenatal Diagnosis-Part of the Turning Pyramid of Prenatal Care.

Authors:  Ran Neiger
Journal:  J Clin Med       Date:  2014-09-05       Impact factor: 4.241

3.  Efficacy of fetal cardiac axis evaluation in the first trimester as a screening tool for congenital heart defect or aneuploidy.

Authors:  Youn-Joon Jung; Bo-Ra Lee; Gwang Jun Kim
Journal:  Obstet Gynecol Sci       Date:  2020-04-07

4.  Cardiac axis evaluation as a screening method for detecting cardiac abnormalities in the first trimester of pregnancy.

Authors:  Florina Nela Oşvar; Adrian Claudiu Raţiu; Florica Voiţă-Mekereş; Gheorghe Florin Voiţă; Mihaela Gabriela Bonţea; Mariana Racoviţă; Gabriel Mihai Mekereş; Florian Dorel Bodog
Journal:  Rom J Morphol Embryol       Date:  2020       Impact factor: 1.033

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.