Literature DB >> 24269144

The dosimetric impact of single, dual, and triple tandem applicators in the treatment of intact uterine cancer.

Skyler B Johnson1, Jessica Zhou1, Shruti Jolly1, Bingqi Guo1, Lisa Young1, Joann I Prisciandaro2.   

Abstract

PURPOSE: To identify an optimal afterloading technique for high-dose-rate brachytherapy treatments in patients with medically inoperable uterine cancer. METHODS AND MATERIALS: Eighteen treatment plans were generated using point and volume-based techniques for three patients using a single, dual, and triple tandem. Dosimetric parameters of the target and critical structures were evaluated.
RESULTS: Similar target coverage was achieved for each patient using volume-based planning; however, differences were evident when comparing point-based plans for the three applicators. In Patient 1, with a cylindrical uterus (8 cm by 4.5 cm), similar results were achieved with all three applicators (V95 [Single]=90.6%, V95 [Dual]=90.6%, and V95 [Triple]=91.5%). In Patient 2, who had a more spherical uterus (5 cm by 5.4 cm), the dual tandem was inferior to the others (V95=65.9% vs. 83.7% with triple and 85.8% with single tandem). Analysis of isodose distributions showed that the dual tandem failed to achieve adequate coverage of the central portion of the fundus. In Patient 3, who had a uterus (6 cm by 5.5 cm) in close proximity to the bladder (0.5 cm) and bowel, both the triple and dual tandem point-based plans achieved better coverage than the single tandem, given dose constraints on the bladder and bowel, with uterus V95 of 83.4% (Triple), 84.9% (Dual), and 73.7% (Single), respectively.
CONCLUSIONS: For inoperable uterine cancer, optimal high-dose-rate applicator selection depends on the anatomy and location of the uterus and critical organs. The triple tandem applicator provides greater latitude in dose and anatomic uterus coverage as compared with either single or dual tandem applicators.
Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Brachytherapy; High-dose-rate; Tandem applicator; Uterine cancer

Mesh:

Year:  2013        PMID: 24269144     DOI: 10.1016/j.brachy.2013.09.005

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  2 in total

Review 1.  Review of advanced catheter technologies in radiation oncology brachytherapy procedures.

Authors:  Jun Zhou; Leonid Zamdborg; Evelyn Sebastian
Journal:  Cancer Manag Res       Date:  2015-07-16       Impact factor: 3.989

2.  Combination of Rotte Y Applicator and Standard Tandem for Medically Inoperable Endometrial Cancer.

Authors:  Yoshiaki Takagawa; Sachiko Izumi; Tomoyuki Okano; Eiichi Takahashi; Yuki Wakamatsu; Midori Kita
Journal:  Adv Radiat Oncol       Date:  2021-09-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.