Literature DB >> 24268822

Clinical analysis of the stability of dental implants after preparation of the site by conventional drilling or piezosurgery.

Ulisses Tavares da Silva Neto1, Julio Cesar Joly2, Sergio Alexandre Gehrke3.   

Abstract

We used resonance frequency analysis to evaluate the implant stability quotient (ISQ) of dental implants that were installed in sites prepared by either conventional drilling or piezoelectric tips. We studied 30 patients with bilateral edentulous areas in the maxillary premolar region who were randomised to have the implant inserted with conventional drilling, or with piezoelectric surgery. The stability of each implant was measured by resonance frequency analysis immediately after placement to assess the immediate stability (time 1) and again at 90 days (time 2) and 150 days (time 3). In the conventional group the mean (SD) ISQ for time 1 was 69.1 (6.1) (95% CI 52.4-77.3); for time 2, 70.7 (5.7) (95% CI 60.4-82.8); and for time 3, 71.7 (4.5) (95% CI 64.2-79.2). In the piezosurgery group the corresponding values were: 77.5 (4.6) (95% CI 71.1-84.3) for time 1, 77.0 (4.2) (95% CI, 69.7-85.2) for time 2, and 79.1 (3.1) (95% CI 74.5-87.3) for time 3. The results showed significant increases in the ISQ values for the piezosurgery group at each time point (p=0.04). The stability of implants placed using the piezoelectric method was greater than that of implants placed using the conventional technique.
Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Conventional drilling; Implant osteotomies; Implant stability; Piezosurgery; Resonance frequency analysis

Mesh:

Substances:

Year:  2013        PMID: 24268822     DOI: 10.1016/j.bjoms.2013.10.008

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  7 in total

1.  Implant stability in different techniques of surgical sites preparation: an in vitro study.

Authors:  C Rastelli; G Falisi; R Gatto; M Galli; E Saccone; M Severino; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

Review 2.  Rotary Instrument or Piezoelectric for the Removal of Third Molars: a Meta-Analysis.

Authors:  Rafael Alvim Magesty; Endi Lanza Galvão; Carolina de Castro Martins; Cássio Roberto Rocha Dos Santos; Saulo Gabriel Moreira Falci
Journal:  J Maxillofac Oral Surg       Date:  2016-07-09

3.  Healing at implants installed in osteotomies prepared either with a piezoelectric device or drills: an experimental study in dogs.

Authors:  Shigeo Fujiwara; Shingo Kato; Franco Bengazi; Joaquin Urbizo Velez; Margherita Tumedei; Mitsuo Kotsu; Daniele Botticelli
Journal:  Oral Maxillofac Surg       Date:  2020-08-15

4.  Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill.

Authors:  Sergio Alexandre Gehrke; Raphaél Bettach; Jaime Sardá Aramburú Júnior; Juan Carlos Prados-Frutos; Massimo Del Fabbro; Jamil Awad Shibli
Journal:  Biomed Res Int       Date:  2018-04-11       Impact factor: 3.411

Review 5.  Piezosurgery in implant dentistry.

Authors:  Stefan Stübinger; Andres Stricker; Britt-Isabelle Berg
Journal:  Clin Cosmet Investig Dent       Date:  2015-11-11

6.  Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone.

Authors:  Luca Lamazza; Girolamo Garreffa; Domenica Laurito; Marco Lollobrigida; Luigi Palmieri; Alberto De Biase
Journal:  Biomed Res Int       Date:  2016-03-24       Impact factor: 3.411

7.  Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial.

Authors:  Claudio Stacchi; Teresa Lombardi; Domenico Baldi; Calogero Bugea; Antonio Rapani; Giuseppe Perinetti; Angelo Itri; David Carpita; Guido Audenino; Giuseppe Bianco; Simone Verardi; Stefano Carossa; Gianmario Schierano
Journal:  Biomed Res Int       Date:  2018-08-14       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.