Literature DB >> 24268793

Measurement of maximum diameter of native abdominal aortic aneurysm by angio-CT: reproducibility is better with the semi-automated method.

C Mora1, C Marcus2, C Barbe3, F Ecarnot4, A Long5.   

Abstract

OBJECTIVES: We sought to identify the technique yielding the best reproducibility from among various measures of native maximum abdominal aortic aneurysm (AAA) diameter with computed tomography angiography (CTA).
METHODS: Ten parameters of maximum diameter in 68 native AAA were measured double-blind by three radiologists on orthogonal planes, curved multiplanar reconstructions, and, finally, using semi-automated software. The semi-automated software creates the AAA lumen centreline and automatically provides cross sections perpendicular to this centreline. The maximum diameter in any direction is automatically calculated once the slice of interest has been selected. Intra- and inter-observer reproducibility and discordance >5 mm were analysed.
RESULTS: Intra-observer reproducibility was high. The limits of agreement were within the clinically accepted range [-5; +5 mm] in 27/30 (90%) comparisons. The method common to all three observers that yielded the lowest values was the semi-automated method. Inter-observer reproducibility was poorer. The limits were outside the clinically accepted range in 26/30 (87%) comparisons. The semi-automated method led to lower intra- (0%) and inter-observer (5.88%) discordances rates.
CONCLUSION: Even using precise methodology, the reproducibility of maximum diameter measurements of native AAA on CTA may exceed recommended thresholds. The semi-automatic method yielded the lower discordance rates and provided a more relevant anatomical approach for measuring the maximum diameter of an AAA.
Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Abdominal aortic aneurysm; Computed tomography; Reproducibility

Mesh:

Year:  2013        PMID: 24268793     DOI: 10.1016/j.ejvs.2013.10.013

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  4 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Maximum Diameter of Native Abdominal Aortic Aneurysm Measured by Angio-Computed Tomography: Reproducibility and Lack of Consensus Impacts on Clinical Decisions.

Authors:  Caroline E Mora; Claude D Marcus; Coralie M Barbe; Fiona B Ecarnot; Anne L Long
Journal:  Aorta (Stamford)       Date:  2015-04-01

3.  Deep Learning Improves the Temporal Reproducibility of Aortic Measurement.

Authors:  Alex Bratt; Daniel J Blezek; William J Ryan; Kenneth A Philbrick; Prabhakar Rajiah; Yasmeen K Tandon; Lara A Walkoff; Jason C Cai; Emily N Sheedy; Panagiotis Korfiatis; Eric E Williamson; Bradley J Erickson; Jeremy D Collins
Journal:  J Digit Imaging       Date:  2021-05-28       Impact factor: 4.903

4.  Geometric and biomechanical modeling aided by machine learning improves the prediction of growth and rupture of small abdominal aortic aneurysms.

Authors:  Moritz Lindquist Liljeqvist; Marko Bogdanovic; Antti Siika; T Christian Gasser; Rebecka Hultgren; Joy Roy
Journal:  Sci Rep       Date:  2021-09-10       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.