Literature DB >> 24268787

Extended (5-year) outcomes of accelerated partial breast irradiation using MammoSite balloon brachytherapy: patterns of failure, patient selection, and dosimetric correlates for late toxicity.

John A Vargo1, Vivek Verma1, Hayeon Kim1, Ronny Kalash1, Dwight E Heron1, Ronald Johnson1, Sushil Beriwal2.   

Abstract

PURPOSE: Accelerated partial breast irradiation (APBI) with balloon and catheter-based brachytherapy has gained increasing popularity in recent years and is the subject of ongoing phase III trials. Initial data suggest promising local control and cosmetic results in appropriately selected patients. Long-term data continue to evolve but are limited outside of the context of the American Society of Breast Surgeons Registry Trial. METHODS AND MATERIALS: A retrospective review of 157 patients completing APBI after breast-conserving surgery and axillary staging via high-dose-rate (192)Ir brachytherapy from June 2002 to December 2007 was made. APBI was delivered with a single-lumen MammoSite balloon-based applicator to a median dose of 34 Gy in 10 fractions over a 5-day period. Tumor coverage and critical organ dosimetry were retrospectively collected on the basis of computed tomography completed for conformance and symmetry.
RESULTS: At a median follow-up time of 5.5 years (range, 0-10.0 years), the 5-year and 7-year actuarial incidences of ipsilateral breast control were 98%/98%, of nodal control 99%/98%, and of distant control 99%/99%, respectively. The crude rate of ipsilateral breast recurrence was 2.5% (n=4); of nodal failure, 1.9% (n=3); and of distant failure, 0.6% (n=1). The 5-year and 7-year actuarial overall survival rates were 89%/86%, with breast cancer-specific survival of 100%/99%, respectively. Good to excellent cosmetic outcomes were achieved in 93.4% of patients. Telangiectasia developed in 27% of patients, with 1-year, 3-year, and 5-year actuarial incidence of 7%/24%/33%; skin dose >100% significantly predicted for the development of telangiectasia (50% vs 14%, P<.0001).
CONCLUSIONS: Long-term single-institution outcomes suggest excellent tumor control, breast cosmesis, and minimal late toxicity. Skin toxicity is a function of skin dose, which may be ameliorated with dosimetric optimization afforded by newer multicatheter brachytherapy applicators and a more rigorous skin dose constraint of ≤100%.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24268787     DOI: 10.1016/j.ijrobp.2013.05.039

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  10 in total

Review 1.  Recent developments and best practice in brachytherapy treatment planning.

Authors:  C D Lee
Journal:  Br J Radiol       Date:  2014-06-02       Impact factor: 3.039

Review 2.  Novel applications of proton therapy in breast carcinoma.

Authors:  John J Cuaron; Shannon M MacDonald; Oren Cahlon
Journal:  Chin Clin Oncol       Date:  2016-08

3.  A PHASE II TRIAL OF BALLOON-CATHETER PARTIAL BREAST BRACHYTHERAPY OPTIMIZATION IN THE TREATMENT OF STAGE 0, I AND IIA BREAST CARCINOMA.

Authors:  Sameer K Nath; Zhe J Chen; Bryan P Rowe; Rachel C Blitzblau; Sanjay Aneja; Baiba J Grube; Nina R Horowitz; Joanne B Weidhaas
Journal:  J Radiat Oncol       Date:  2014-12

Review 4.  Relationship and interactions of curcumin with radiation therapy.

Authors:  Vivek Verma
Journal:  World J Clin Oncol       Date:  2016-06-10

5.  The incidence of fat necrosis in balloon-based breast brachytherapy.

Authors:  Nitesh N Paryani; Laura Vallow; Wilza Magalhaes; Michael G Heckman; Siyong Kim; Ashley Smith; Nancy N Diehl; Sarah McLaughlin
Journal:  J Contemp Brachytherapy       Date:  2015-03-05

6.  High-dose-rate interstitial brachytherapy for accelerated partial breast irradiation - trial results of Azerbaijan National Center of Oncology.

Authors:  Jamil A Aliyev; Isa H Isayev; Kamal S Akbarov; Samir S Qurbanov; Ruslan R Huseynov; Nigar S Aliyeva
Journal:  J Contemp Brachytherapy       Date:  2017-04-13

7.  A systematic review of clinical outcomes and radiotherapy-associated toxicity in multicatheter accelerated partial breast irradiation.

Authors:  Yang Lv; Lin He; Chao Wang; Lijiu Zhang; Biyuan Zhang; Yuhua Song
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

8.  Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes.

Authors:  Zaker Rana; Nadim M Nasr; Huaying Ji; Virginia Lorio; Stephanie Akbari; Molly Sebastian; Mami Martin; Robert L Hong
Journal:  Radiat Oncol       Date:  2015-07-31       Impact factor: 3.481

9.  A 3D computer-assisted treatment planning system for breast cancer brachytherapy treatment.

Authors:  Yuchong Rachel Jiang; Edward R Sykes
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07-08       Impact factor: 2.924

10.  First Experience in Korea of Stereotactic Partial Breast Irradiation for Low-Risk Early-Stage Breast Cancer.

Authors:  Won Hee Lee; Jee Suk Chang; Min Jung Kim; Vivian Youngjean Park; Jung Hyun Yoon; Se Young Kim; Jee Ye Kim; Hyung Seok Park; Seung Il Kim; Young Up Cho; Byeong Woo Park; Yong Bae Kim
Journal:  Front Oncol       Date:  2020-04-29       Impact factor: 6.244

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.