Evaluation of taper joints with combined fatigue and crevice corrosion testing: comparison to human explanted modular prostheses.

L Reclaru1, R A Brooks, M Zuberbühler, P-Y Eschler, F Constantin, G Tomoaia.   

Abstract

The requirement for revision surgery of total joint replacements is increasing and modular joint replacement implants have been developed to provide adjustable prosthetic revision systems with improved intra-operative flexibility. An electrochemical study of the corrosion resistance of the interface between the distal and proximal modules of a modular prosthesis was performed in combination with a cyclic fatigue test. The complexity resides in the existence of interfaces between the distal part, the proximal part, and the dynamometric screw. A new technique for evaluating the resistance to cyclic dynamic corrosion with crevice stimulation was used and the method is presented. In addition, two components of the proximal module of explanted Ti6Al4V and Ti6Al7Nb prostheses were investigated by optical and electron microscopy. Our results reveal that: The electrolyte penetrates into the interface between the distal and proximal modules during cyclic dynamic fatigue tests, the distal module undergoes cracking and corrosion was generated at the interface between the two models; The comparison of the explanted proximal parts with the similar prostheses evaluated following cyclic dynamic crevice corrosion testing showed that there were significant similarities indicating that this method is suitable for evaluating materials used in the fabrication of modular prostheses.
© 2013. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Explanted prosthesis; Fatigue corrosion; Modular prosthesis

Mesh:

Substances:

Year:  2013        PMID: 24268235     DOI: 10.1016/j.msec.2013.10.005

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  3 in total

Review 1.  Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches.

Authors:  Divya Rani Bijukumar; Abhijith Segu; Júlio C M Souza; XueJun Li; Mark Barba; Louis G Mercuri; Joshua J Jacobs; Mathew Thoppil Mathew
Journal:  Nanomedicine       Date:  2018-01-12       Impact factor: 5.307

2.  Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study.

Authors:  Dmitry Royhman; Robin Pourzal; Deborah Hall; Hannah J Lundberg; Markus A Wimmer; Joshua Jacobs; Nadim J Hallab; Mathew T Mathew
Journal:  J Mech Behav Biomed Mater       Date:  2021-03-12

3.  Comparative Analysis of the Corrosion Resistance of Titanium Alloys Intended to Come into Direct or Prolonged Contact with Live Tissues.

Authors:  Florina Ionescu; Lucien Reclaru; Lavinia Cosmina Ardelean; Andreas Blatter
Journal:  Materials (Basel)       Date:  2019-09-03       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.