Literature DB >> 2426389

Fluctuation analysis of nonideal shot noise. Application to the neuromuscular junction.

R Fesce, J R Segal, W P Hurlbut.   

Abstract

Procedures are described for analyzing shot noise and determining the waveform, w(t), mean amplitude, (h), and mean rate of occurrence, (r), of the shots under a variety of nonideal conditions that include: (a) slow, spurious changes in the mean, (b) nonstationary shot rates, (c) nonuniform distribution of shot amplitudes, and (d) nonlinear summation of the shots. The procedures are based upon Rice's (1944. Bell Telephone System Journal. 23: 282-332) extension of Campbell's theorem to the second (variance), lambda 2, third (skew), lambda 3, and fourth, lambda 4, semi-invariants (cumulants) of the noise. It is shown that the spectra of lambda 2 and lambda 3 of nonstationary shot noise contain a set of components that are proportional to (r) and arise from w(t), and a set of components that are independent of (r) and arise from the temporal variations in r(t). Since the latter components are additive and are limited by the bandwidth of r(t), they can be removed by appropriate filters; then (r) and (h) can be determined from the lambda 2 and lambda 3 of the filtered noise. We also show that a factor related to the ratio (lambda 3)2/(lambda 2)(lambda 4) monitors the spread in the distribution of shot amplitudes and can be used to correct the estimates of (r) and (h) for the effects of that spread, if the shape of the distribution is known and if r(t) is stationary. The accuracy of the measurements of lambda 4 is assessed and corrections for the effects of nonlinear summation of lambda 2, lambda 3, and lambda 4 are derived. The procedures give valid results when they are used to analyze shot noise produced by the (linear) summation of simulated miniature endplate potentials, which are generated either at nonstationary rates or with a distribution of amplitudes.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2426389      PMCID: PMC2228789          DOI: 10.1085/jgp.88.1.25

Source DB:  PubMed          Journal:  J Gen Physiol        ISSN: 0022-1295            Impact factor:   4.086


  9 in total

1.  Estimating transmitter release rates from postsynaptic current fluctuations.

Authors:  E Neher; T Sakaba
Journal:  J Neurosci       Date:  2001-12-15       Impact factor: 6.167

2.  Correlation between quantal secretion and vesicle loss at the frog neuromuscular junction.

Authors:  W P Hurlbut; N Iezzi; R Fesce; B Ceccarelli
Journal:  J Physiol       Date:  1990-06       Impact factor: 5.182

3.  A re-examination of the effects of lanthanum on the frog neuromuscular junction.

Authors:  A J Dekhuijzen; N Iezzi; W P Hurlbut
Journal:  Pflugers Arch       Date:  1989-09       Impact factor: 3.657

4.  Open channel noise. VI. Analysis of amplitude histograms to determine rapid kinetic parameters.

Authors:  S H Heinemann; F J Sigworth
Journal:  Biophys J       Date:  1991-09       Impact factor: 4.033

5.  Making quantal analysis more convenient, fast, and accurate: user-friendly software QUANTAN.

Authors:  Maria Bykhovskaia
Journal:  J Neurosci Methods       Date:  2007-10-23       Impact factor: 2.390

6.  Analysis of quantal acetylcholine noise at end-plates of frog muscle during rapid transmitter secretion.

Authors:  P C Molenaar; B S Oen
Journal:  J Physiol       Date:  1988-06       Impact factor: 5.182

7.  The effect of potassium on exocytosis of transmitter at the frog neuromuscular junction.

Authors:  B Ceccarelli; R Fesce; F Grohovaz; C Haimann
Journal:  J Physiol       Date:  1988-07       Impact factor: 5.182

8.  Effect of alpha-latrotoxin on the frog neuromuscular junction at low temperature.

Authors:  B Ceccarelli; W P Hurlbut; N Iezzi
Journal:  J Physiol       Date:  1988-08       Impact factor: 5.182

9.  Light reduces the excitation efficiency in the nss mutant of the sheep blowfly Lucilia.

Authors:  S Barash; E Suss; D G Stavenga; C T Rubinstein; Z Selinger; B Minke
Journal:  J Gen Physiol       Date:  1988-09       Impact factor: 4.086

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.