Literature DB >> 24261382

Why are patients noncompliant with follow-up recommendations after MRI-guided core needle biopsy of suspicious breast lesions?

Matthew O Thompson1, Jafi Lipson, Bruce Daniel, Chivonne Harrigal, Paul Mullarkey, Sunita Pal, Atalie C Thompson, Debra Ikeda.   

Abstract

OBJECTIVE: The objective of this study was to investigate patient and breast MRI characteristics associated with noncompliance with recommended follow-up after MRI-guided core needle biopsy of suspicious breast lesions.
MATERIALS AND METHODS: A retrospective review was performed of 576 breast lesions biopsied under MRI guidance between 2007 and 2010. Patient follow-up was obtained from the medical record and from contact with referring physicians.
RESULTS: Of 415 women who underwent 576 MRI-guided core needle biopsies for suspicious breast lesions, 123 (29.6%) patients representing 154 of 576 (26.7%) lesions were noncompliant with recommended excision or 6-month MRI follow-up. Referring physicians provided information for 63% (97/154) of lesions in noncompliant patients, of which 49.5% (48/97) were followed by mammography instead of excision or MRI. Noncompliance with MRI follow-up was significantly associated with referral for biopsy by outside hospital physicians (odds ratio [OR], 2.40; p = 0.0001) and with referral for screening MRI (1.46; p = 0.093) and biopsy of a focus or foci lesion (1.63; p = 0.088). Among 178 lesions in patients compliant with follow-up MRI after MRI-guided core needle biopsy, 7.9% (14/178) had abnormal follow-up MRI results, half of which (3.9%, 7/178) were found on repeat biopsy to be high-risk or malignant.
CONCLUSION: Institutions performing MRI-guided core biopsies should be aware that patients referred from outside institutions are more likely to be noncompliant with recommended follow-up. Strategies to improve follow-up should include educating patients on the difference between mammography and MRI follow-up.

Entities:  

Mesh:

Year:  2013        PMID: 24261382     DOI: 10.2214/AJR.12.10282

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  1 in total

1.  Short interval follow-up after a benign concordant MR-guided vacuum assisted breast biopsy--is it worthwhile?

Authors:  Sara D Shaylor; Samantha L Heller; Amy N Melsaether; Dipti Gupta; Avani Gupta; James Babb; Linda Moy
Journal:  Eur Radiol       Date:  2014-03-14       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.