Literature DB >> 24256708

Carotid artery wall motion analysis from B-mode ultrasound using adaptive block matching: in silico evaluation and in vivo application.

A Gastounioti1, S Golemati, J S Stoitsis, K S Nikita.   

Abstract

Valid risk stratification for carotid atherosclerotic plaques represents a crucial public health issue toward preventing fatal cerebrovascular events. Although motion analysis (MA) provides useful information about arterial wall dynamics, the identification of motion-based risk markers remains a significant challenge. Considering that the ability of a motion estimator (ME) to handle changes in the appearance of motion targets has a major effect on accuracy in MA, we investigated the potential of adaptive block matching (ABM) MEs, which consider changes in image intensities over time. To assure the validity in MA, we optimized and evaluated the ABM MEs in the context of a specially designed in silico framework. ABM(FIRF2), which takes advantage of the periodicity characterizing the arterial wall motion, was the most effective ABM algorithm, yielding a 47% accuracy increase with respect to the conventional block matching. The in vivo application of ABM(FIRF2) revealed five potential risk markers: low movement amplitude of the normal part of the wall adjacent to the plaques in the radial (RMA(PWL)) and longitudinal (LMA(PWL)) directions, high radial motion amplitude of the plaque top surface (RMA(PTS)), and high relative movement, expressed in terms of radial strain (RSI(PL)) and longitudinal shear strain (LSSI(PL)), between plaque top and bottom surfaces. The in vivo results were reproduced by OF(LK(WLS)) and ABM(KF-K2), MEs previously proposed by the authors and with remarkable in silico performances, thereby reinforcing the clinical values of the markers and the potential of those MEs. Future in vivo studies will elucidate with confidence the full potential of the markers.

Entities:  

Mesh:

Year:  2013        PMID: 24256708     DOI: 10.1088/0031-9155/58/24/8647

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  A semiautomatic method for in vivo three-dimensional quantitative analysis of fascial layers mobility based on 3D ultrasound scans.

Authors:  S Condino; G Turini; S Parrini; A Stecco; F Busoni; V Ferrari; M Ferrari; M Gesi
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-03-06       Impact factor: 2.924

2.  Motion synchronisation patterns of the carotid atheromatous plaque from B-mode ultrasound.

Authors:  Spyretta Golemati; Eleni Patelaki; Aimilia Gastounioti; Ioannis Andreadis; Christos D Liapis; Konstantina S Nikita
Journal:  Sci Rep       Date:  2020-07-08       Impact factor: 4.379

3.  A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences.

Authors:  Qinghui Zhang; Junqiu Li; Zhenping Qiang; Libo He
Journal:  Biomed Res Int       Date:  2019-11-21       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.