X-ray microtomography of biological tissues using laboratory and synchrotron sources.

J C Elliott1, D K Bowen, S D Dover, S T Davies.   

Abstract

X-ray microradiography is a well established technique for the study of biological structures in which the projected absorption is measured, usually with photographic film or resist. If scanning X-ray microradiography with a 15-μm beam, 2-D scanning, and photon counting is used, more accurate results can be obtained and real-time experiments undertaken. Addition of a rotation axis allows computerized axial tomography to be done at a resolution of 15 μm. This technique overcomes the inherent difficulty of microradiography that all detail perpendicular to the plane of the specimen is superimposed. This method has been applied to the study of the 3-D mineral distribution in a 0.8×0.8 mm column of human cortical bone with a laboratory X-ray source. Calculation of the wavelength dependence of the linear absorption coefficient for liver and bone shows that, for a choice of wavelength in the range of 3-0.4 Å (4-30 keV), the specimen thickness can be from 100μm-2 cm and 10 μm-3 mm, respectively.Synchrotron X-radiation has the potential for better resolution because of the higher intensity, which allows the use of a narrower beam. There is also the possibility of determining individual element 3-D distributions from measurements on either side of the absorption edges because of the continuous nature of the spectrum and also the possibility of doing this from X-ray fluorescence measurements. To investigate these possibilities, a tomographic apparatus has been built based on the availability of accurately ground, tungsten carbide balls. Metrological assessment shows that the specimen remains within <1 μm of the required position during translation and rotation. Preliminary X-ray tomographic studies with a 4-μm diameter beam have been started at the Daresbury laboratory synchrotron source.

Entities:  

Year:  1987        PMID: 24254678     DOI: 10.1007/BF02796634

Source DB:  PubMed          Journal:  Biol Trace Elem Res        ISSN: 0163-4984            Impact factor:   3.738


  5 in total

1.  Scanning X-ray microradiographic study of the formation of caries-like lesions in synthetic apatite aggregates.

Authors:  P Anderson; J C Elliott
Journal:  Caries Res       Date:  1985       Impact factor: 4.056

2.  Computerized transverse axial scanning (tomography). 1. Description of system.

Authors:  G N Hounsfield
Journal:  Br J Radiol       Date:  1973-12       Impact factor: 3.039

3.  A scanning x-ray microscope using synchrotron radiation.

Authors:  P Horowitz; J A Howell
Journal:  Science       Date:  1972-11-10       Impact factor: 47.728

4.  Three-dimensional distribution of mineral in bone at a resolution of 15 micron determined by x-ray microtomography.

Authors:  J C Elliott; S D Dover
Journal:  Metab Bone Dis Relat Res       Date:  1984

5.  X-ray microscopy using computerized axial tomography.

Authors:  J C Elliott; S D Dover
Journal:  J Microsc       Date:  1985-06       Impact factor: 1.758

  5 in total
  1 in total

Review 1.  In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science.

Authors:  Sheridan C Mayo; Andrew W Stevenson; Stephen W Wilkins
Journal:  Materials (Basel)       Date:  2012-05-24       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.