Literature DB >> 24248977

Suspended trapping gas chromatography I fourier transform mass spectrometry for analysis of complex organic mixtures.

J D Hogan1, D A Laude.   

Abstract

The superior sensitivity , dynamic range, and mass measurement accuracy of suspended trapping pulse sequences for gas chromatography combined with Fourier transform mass spectrometry (GC/FTMS) separations of complex organic mixtures is demonstrated. By combining intense ionization conditions with a suspended trapping event prior to detection the working range of the trapped ion cell is increased by 10(3) . Improved detection limits are shown for the GC/FTMS separation of a peppermint oil, with the suspended trapping total ion chromatogram yielding 28 peaks, compared with 15 with a conventional trapping pulse sequence. A fivefold to fifteenfold improvement in signal-to-noise for suspended trapping measurements is also demonstrated with comparison spectra from separations of an unleaded gasoline sample. Suspended trapping spectra show little mass discrimination when an external ion reservoir is used, and chromatographic peak heights differ from conventional spectra by less than 30% if the initial ion population is within the space charge limit of the cell. Finally, average wide band mass measurement errors for components differing in concentration by several orders of magnitude are improved by a factor of 6 to 20 with suspended trapping compared with conventional trapping . For example, average errors of 8.7 ppm are obtained for a suspended trapping GC/FTMS separation of peppermint oil from a single calibration table in which the analysis is perfonned in the absence of calibrant.

Entities:  

Year:  1990        PMID: 24248977     DOI: 10.1016/1044-0305(90)85026-I

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  6 in total

1.  Extension of dynamic range in Fourier transform ion cyclotron resonance mass spectrometry via stored waveform inverse Fourier transform excitation.

Authors:  T C Wang; T L Ricca; A G Marshall
Journal:  Anal Chem       Date:  1986-12       Impact factor: 6.986

Review 2.  Hyphenated techniques for analysis of complex organic mixtures.

Authors:  C L Wilkins
Journal:  Science       Date:  1983-10-21       Impact factor: 47.728

3.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

4.  Linked gas chromatography/Fourier transform infrared/Fourier transform mass spectrometry with integrated electron impact and chemical ionization.

Authors:  D A Laude; G M Brissey; C F Ijames; R S Brown; C L Wilkins
Journal:  Anal Chem       Date:  1984-06       Impact factor: 6.986

5.  Gas chromatography/multiphoton ionization Fourier transform mass spectrometry.

Authors:  T M Sack; D A McCrery; M L Gross
Journal:  Anal Chem       Date:  1985-06       Impact factor: 6.986

6.  Desorption ionization of cesium iodide by Fourier transform mass spectrometry.

Authors:  M E Castro; D H Russell
Journal:  Anal Chem       Date:  1985-10       Impact factor: 6.986

  6 in total
  2 in total

1.  Combining low and high mass ion accumulation for enhancing shotgun proteome analysis by accurate mass measurement.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-18       Impact factor: 3.109

2.  Experimental evaluation of a hyperbolic ion trap for fourier transform ion cyclotron resonance mass spectrometry.

Authors:  W W Yin; M Wang; A G Marshall; E B Ledford
Journal:  J Am Soc Mass Spectrom       Date:  1992-03       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.