Literature DB >> 24247552

Label-free detection of gliadin food allergen mediated by real-time apta-PCR.

Alessandro Pinto1, Pedro Nadal Polo, Olivier Henry, M Carmen Bermudo Redondo, Marketa Svobodova, Ciara K O'Sullivan.   

Abstract

Celiac disease is an immune-mediated enteropathy triggered by the ingestion of gluten. The only effective treatment consists in a lifelong gluten-free diet, requiring the food industry to tightly control the gluten contents of their products. To date, several gluten quantification approaches using antibodies are available and recommended by the legal authorities, such as Codex Alimentarius. However, whilst these antibody-based tests exhibit high sensitivity and specificity, the production of antibodies inherently requires the killing of host animals and is time-consuming and relatively expensive. Aptamers are structured single-stranded nucleic acid ligands that bind with high affinity and specificity to their cognate target, and aiming for a cost-effective viable alternative to the use of antibodies. Herein, we report the systematic evolution of ligands by exponential enrichment (SELEX)-based selection of a DNA aptamer against gliadin from a combinatorial DNA library and its application in a novel detection assay. Taking into account the hydrophobic nature of the gliadin target, a microtitre plate format was exploited for SELEX, where the target was immobilised via hydrophobic interactions, thus exposing aptatopes accessible for interaction with the DNA library. Evolution was followed using surface plasmon resonance, and following eight rounds of SELEX, the enriched DNA pool was cloned, sequenced and a clear consensus motif was identified. An apta-PCR assay was developed where competition for the aptamer takes place between the surface-immobilised gliadin and gliadin in the target sample, akin to an ELISA competitive format where the more target present in the sample, the less aptamer will bind to the immobilised gliadin. Following competition, any aptamer bound to the immobilised gliadin was heat-eluted and quantitatively amplified using real-time PCR, achieving a detection limit of approx. 2 nM (100 ng mL(-1)). The specificity of the selected aptamer was demonstrated and no cross-reactivity was observed with streptavidin, bovine serum albumin or anti-gliadin IgG.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24247552     DOI: 10.1007/s00216-013-7475-z

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

Review 1.  Selected Instrumental Techniques Applied in Food and Feed: Quality, Safety and Adulteration Analysis.

Authors:  Graciela Artavia; Carolina Cortés-Herrera; Fabio Granados-Chinchilla
Journal:  Foods       Date:  2021-05-13

Review 2.  Harnessing Aptamers to Overcome Challenges in Gluten Detection.

Authors:  Rebeca Miranda-Castro; Noemí de-los-Santos-Álvarez; Arturo J Miranda-Ordieres; María Jesús Lobo-Castañón
Journal:  Biosensors (Basel)       Date:  2016-04-20

Review 3.  Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens.

Authors:  Alina Vasilescu; Gilvanda Nunes; Akhtar Hayat; Usman Latif; Jean-Louis Marty
Journal:  Sensors (Basel)       Date:  2016-11-05       Impact factor: 3.576

Review 4.  Gluten Detection Methods and Their Critical Role in Assuring Safe Diets for Celiac Patients.

Authors:  Claudia E Osorio; Jaime H Mejías; Sachin Rustgi
Journal:  Nutrients       Date:  2019-12-02       Impact factor: 5.717

  4 in total