Literature DB >> 24246614

Reliability of the measurement of the abdominal aortic diameter by novice operators using a pocket-sized ultrasound system.

Tiphaine Bonnafy1, Philippe Lacroix, Iléana Desormais, Anaïs Labrunie, Benoit Marin, Aurélien Leclerc, Aïda Oueslati, Florence Rollé, Philippe Vignon, Victor Aboyans.   

Abstract

BACKGROUND: Despite favorable results of randomized studies and several guidelines, screening for abdominal aortic aneurysm is poorly implemented in most countries. In order to implement an effective abdominal aortic aneurysm screening programme, training of physicians other than cardiovascular imaging specialists is necessary. Also, the use of pocket-sized ultrasound systems seems an appealing alternative to conventional echography machines for large-scale screening. AIMS: To test the hypothesis that, after a short period of specific training with a pocket-sized ultrasound system, novice operators could reliably measure the abdominal aortic diameter. We assessed the agreement between abdominal aortic diameter measurements from novice operators using a pocket-sized ultrasound system and experts using conventional machines.
METHODS: After focused training of novice operators, the abdominal aortic diameter was independently measured at least four times: by two experts using conventional ultrasound, by one expert using a pocket-sized ultrasound system and by at least one novice operator using the pocket-sized system; each operator was blinded to the others.
RESULTS: The aortic diameters of 56 patients were measured. The intraclass correlation coefficients between the four sets of measurement were all>0.91 and the mean difference between the measurements was negligible (<1mm). The interoperator variability for experts using conventional machines versus novices using pocket-sized machines was ≤ 4mm in 92.0% of cases. No learning curve over time was noted.
CONCLUSION: In order to screen for abdominal aortic aneurysm, the abdominal aortic diameter can be accurately measured by non-specialist physicians with pocket-sized ultrasound devices after a short period of training.
Copyright © 2013. Published by Elsevier Masson SAS.

Entities:  

Keywords:  AAA; Abdominal aortic aneurysm; Anévrysme de l’aorte abdominale; CI; Dépistage; Experience; Expérience; Fiabilité; ICC; NHS; National Health Service; Reliability; Screening; Ultrasound; abdominal aortic aneurysm; confidence interval; intraclass correlation coefficient; Échographe de poche

Mesh:

Year:  2013        PMID: 24246614     DOI: 10.1016/j.acvd.2013.08.004

Source DB:  PubMed          Journal:  Arch Cardiovasc Dis        ISSN: 1875-2128            Impact factor:   2.340


  8 in total

Review 1.  POCUS in Internal Medicine Curriculum: Quest for the Holy-Grail of Modern Medicine.

Authors:  Devyani Ramgobin; Vasu Gupta; Rea Mittal; Lilly Su; Meet A Patel; Nour Shaheen; Sachin Gupta; Rohit Jain
Journal:  J Community Hosp Intern Med Perspect       Date:  2022-09-09

2.  Expert Facilitated Development of an Objective Assessment Tool for Point-of-Care Ultrasound Performance in Undergraduate Medical Education.

Authors:  Holly Black; Gillian Sheppard; Brian Metcalfe; Jordan Stone-McLean; Heather McCarthy; Adam Dubrowski
Journal:  Cureus       Date:  2016-06-10

3.  Faculty development in point of care ultrasound for internists.

Authors:  Anna Maw; Cathy Jalali; Deanna Jannat-Khah; Kirana Gudi; Lia Logio; Arthur Evans; Stacy Anderson; Joshua Smith
Journal:  Med Educ Online       Date:  2016-12-13

Review 4.  Hand-held Ultrasound Scanners in Medical Education: A Systematic Review.

Authors:  Victor Galusko; Mohammed Yunus Khanji; Owen Bodger; Clive Weston; John Chambers; Adrian Ionescu
Journal:  J Cardiovasc Ultrasound       Date:  2017-09-29

5.  Abdominal aortic aneurysm screening program using hand-held ultrasound in primary healthcare.

Authors:  Antoni Sisó-Almirall; Belchin Kostov; Marta Navarro González; Daniel Cararach Salami; Alfonso Pérez Jiménez; Rosa Gilabert Solé; Concepció Bru Saumell; Lluís Donoso Bach; Mireia Villalta Martí; Luis González-de Paz; Rafael Ruiz Riera; Vicenç Riambau Alonso; Nihan Acar-Denizli; Marta Farré Almacellas; Manuel Ramos-Casals; Jaume Benavent Àreu
Journal:  PLoS One       Date:  2017-04-28       Impact factor: 3.240

6.  The reproducibility of measuring maximum abdominal aortic aneurysm diameter from ultrasound images.

Authors:  Evan O Matthews; Jenna Pinchbeck; Kylie Elmore; Rhondda E Jones; Joseph V Moxon; Jonathan Golledge
Journal:  Ultrasound J       Date:  2021-02-26

Review 7.  Screening for aneurysms of the abdominal aorta using a simple screening device.

Authors:  J W Brakel; T A Berendsen; P M C Callenbach; J van der Burgh; R J Hissink; M van den Berg
Journal:  Ultrasound J       Date:  2020-11-11

8.  Abdominal aorta measurements by a handheld ultrasound device compared with a conventional cart-based ultrasound machine.

Authors:  Abdulrahman M Alfuraih; Abdulaziz I Alrashed; Saleh O Almazyad; Mohammed J Alsaadi
Journal:  Ann Saudi Med       Date:  2021-12-02       Impact factor: 1.526

  8 in total