Quantitative analysis of crude plasma extracts by ion trap tandem mass spectrometry.

R J Strife1, J R Simms.   

Abstract

The ion trap mass spectrometer is a tandem-in-time instrument that has promise as an extremely sensitive device for practical tandem mass spectrometry assays. An approach for the quantitative analysis of unknown drug levels in crude extracts, using combined capillary gas chromatography and the ion trap mass spectrometer in the tandem mode, is described. One-gram plasma samples were spiked with an anti-inflammatory drug at levels of 1-100 ng, and with 50 ng of a chemical analog internal standard. Crude extracts of the plasma samples are analyzed by using scan functions that utilize combined radiofrequency (rf) and de voltages. The need for combined rf- and de-voltage sequences for analysis of such extracts is demonstrated by comparison to attempted analyses using only rf voltages. Limitations of the method are: (1) the need for accurate calibration of ionization times to obtain linear calibration lines, and (2) the lack of automatic gain control for scans using combined rf and dc voltages to control and optimize parent ion populations and to allow a simpler analysis of "unknowns. "

Entities:  

Year:  1992        PMID: 24243048     DOI: 10.1016/1044-0305(92)87065-7

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  3 in total

1.  Tandem mass spectrometry of prostaglandins: a comparison of an ion trap and a reversed geometry sector instrument.

Authors:  R J Strife; P E Kelley; M Weber-Grabau
Journal:  Rapid Commun Mass Spectrom       Date:  1988-06       Impact factor: 2.419

2.  Long-term performance of a gas chromatography/tandem mass spectrometry assay for tebufelone in plasma.

Authors:  R L Dobson; D M Neal; B R DeMark; S R Ward
Journal:  Anal Chem       Date:  1990-09-01       Impact factor: 6.986

3.  An automatic reaction control chemical ionization technique in ion trap detector for quantitative plasma profding of arecoline in treated alzheimer patients.

Authors:  H U Shetty; E M Daly; N H Greig; S I Rapoport; T T Soncrant
Journal:  J Am Soc Mass Spectrom       Date:  1991-04       Impact factor: 3.109

  3 in total
  1 in total

1.  Negative chemical ionization in quadrupole ion trap mass spectrometry: Effects of applied voltages and reaction times.

Authors:  D W Berberich; R A Yost
Journal:  J Am Soc Mass Spectrom       Date:  1994-08       Impact factor: 3.109

  1 in total