Literature DB >> 24242093

Isotope dilution gas chromatography/mass spectrometry for platinum determination in urine.

S K Aggarwal1, M Kinter, D A Herold.   

Abstract

The therapeutic importance of platinum (Pt) compounds, the growing accessibility of gas chromatography/mass spectrometry (GC/MS) systems in clinical laboratories, and the lack of a mass spectrometric method for the determination of Pt in biological samples motivated us to develop an isotope dilution GC/MS assay for Pt. The method is based on the use of lithium bis(trifluoroethyl) dithiocarbamate, Li(FDEDTC), as a chelating agent and enriched (192)Pt for isotope dilution. Conditions were optimized for the precise and accurate determination of isotope ratios of Pt by using a 10-m DB-l fused silica capillary column and a reverse-geometry double-focusing mass spectrometer with selected ion monitoring. An overall precision of 1% was obtained by combining within-run precision and between-run precision at the 10-ng level. No appreciable memory effect was observed when samples with different isotope ratios were analyzed sequentially. The method was validated by the quantitation of Pt in National Institute of Standards and Technology freeze-dried urine sample SRM 2670. A concentration value of 125 ± 6 /Lg/L (n = 6) was obtained by using four different sets of isotope ratios in the molecular ion and supports the National Institute of Standards and Technology recommended value of 120 ± ? μg/L. Limits-of-quantitation, estimated at 3 μg/L, are made possible by the high sensitivity of the method and the low blank value for Pt.

Entities:  

Year:  1991        PMID: 24242093     DOI: 10.1016/1044-0305(91)80065-F

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  6 in total

1.  Isotopic analysis of chromium in lunar materials by mass spectrometry of the trifluoroacetylacetonate.

Authors:  N M Frew; J J Leary; T L Isenhour
Journal:  Anal Chem       Date:  1972-04-01       Impact factor: 6.986

2.  Determination of chromium in urine by stable isotope dilution gas chromatography/mass spectrometry using lithium bis(trifluoroethyl)dithiocarbamate as a chelating agent.

Authors:  S K Aggarwal; M Kinter; M R Wills; J Savory; D A Herold
Journal:  Anal Chem       Date:  1990-01-15       Impact factor: 6.986

3.  Determination of chromium in biological materials by stable isotope dilution.

Authors:  C Veillon; W R Wolf; B E Guthrie
Journal:  Anal Chem       Date:  1979-06       Impact factor: 6.986

4.  Determination of selenium in biological materials by stable isotope dilution gas chromatography-mass spectrometry.

Authors:  D C Reamer; C Veillon
Journal:  Anal Chem       Date:  1981-12       Impact factor: 6.986

5.  Isotope dilution gas chromatography/mass spectrometry for the determination of nickel in biological materials.

Authors:  S K Aggarwal; M Kinter; M R Wills; J Savory; D A Herold
Journal:  Anal Chem       Date:  1989-05-15       Impact factor: 6.986

6.  A double isotope dilution method for using stable selenium isotopes in metabolic tracer studies: analysis by gas chromatography/mass spectrometry (GC/MS).

Authors:  D C Reamer; C Veillon
Journal:  J Nutr       Date:  1983-04       Impact factor: 4.798

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.